Evaluation of Clinical Outcomes of an Isofocal Optic-Design Intraocular Lens with Double C-Loop Haptics in Eyes with Glaucoma

Background/Objectives: To assess the refractive and visual outcomes after implantation of an isofocal optic-design intraocular lens (IOL) with double C-loop haptics following cataract surgery in eyes with primary open-angle glaucoma (POAG). Methods: This was a prospective, open-label, interventional exploratory study that considered POAG eyes undergoing cataract surgery with implantation of the Isopure Serenity (Beaver-Visitec International, Inc. [BVI], Waltham, MA, USA) IOL. Primary outcomes measured included manifest refraction, monocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA) and distance-corrected intermediate visual acuity (DCIVA) at 80 and 66 cm, uncorrected near visual acuity (UNVA), and distance-corrected near visual acuity (DCNVA) at 40 cm, and photopic binocular defocus curve were evaluated 3 months after surgery. Results: In total, 22 eyes of 11 patients (nine women, mean age of 68.3 ± 8.3 years) with POAG were enrolled and completed the clinical study. The study found that 100% of the eyes were within ±0.50 D and 86.36% of the eyes showed a postoperative refractive cylinder ≤ 0.25 D. The mean spherical equivalent and refractive cylinder were −0.06 ± 0.30 D and −0.13 ± 0.33 D, respectively. It was also shown that 86.36% and 100% of the eyes had 20/20 or better UDVA and CDVA, respectively. Furthermore, 95.45% and 77.27% of eyes presented a monocular DCIVA value of ≥20/32 at 80 and 66 cm, respectively, and 68.18% of eyes presented a monocular DCNVA value of ≥20/40. The mean monocular CDVA, DCIVA at 80 cm, DCIVA at 66 cm, and DCNVA were −0.09 ± 0.04, 0.12 ± 0.07, 0.21 ± 0.07 and 0.32 ± 0.07 logMAR, respectively. The binocular defocus curve showed good visual acuity at distance and intermediate vision. Conclusions: The isofocal Isopure Serenity IOL can be implanted in eyes with POAG after cataract surgery, achieving a satisfactory visual performance. Our results suggest that this IOL model is a viable option for selected patients with controlled early/moderate POAG and without central visual field involvement diagnosed with cataracts.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-07-22
DOI
https://doi.org/10.3390/jcm15145730
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Clinical Outcomes of an Isofocal Optic-Design Intraocular Lens with Double C-Loop Haptics in Eyes with Glaucoma

Takayuki Akahoshi
Journal of Clinical Medicine
Ophthalmology and Visual Impairment Studies
article

Evaluation of Clinical Outcomes of an Isofocal Optic-Design Intraocular Lens with Double C-Loop Haptics in Eyes with Glaucoma

Takayuki Akahoshi
article en

Abstract

Background/Objectives: To assess the refractive and visual outcomes after implantation of an isofocal optic-design intraocular lens (IOL) with double C-loop haptics following cataract surgery in eyes with primary open-angle glaucoma (POAG). Methods: This was a prospective, open-label, interventional exploratory study that considered POAG eyes undergoing cataract surgery with implantation of the Isopure Serenity (Beaver-Visitec International, Inc. [BVI], Waltham, MA, USA) IOL. Primary outcomes measured included manifest refraction, monocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA) and distance-corrected intermediate visual acuity (DCIVA) at 80 and 66 cm, uncorrected near visual acuity (UNVA), and distance-corrected near visual acuity (DCNVA) at 40 cm, and photopic binocular defocus curve were evaluated 3 months after surgery. Results: In total, 22 eyes of 11 patients (nine women, mean age of 68.3 ± 8.3 years) with POAG were enrolled and completed the clinical study. The study found that 100% of the eyes were within ±0.50 D and 86.36% of the eyes showed a postoperative refractive cylinder ≤ 0.25 D. The mean spherical equivalent and refractive cylinder were −0.06 ± 0.30 D and −0.13 ± 0.33 D, respectively. It was also shown that 86.36% and 100% of the eyes had 20/20 or better UDVA and CDVA, respectively. Furthermore, 95.45% and 77.27% of eyes presented a monocular DCIVA value of ≥20/32 at 80 and 66 cm, respectively, and 68.18% of eyes presented a monocular DCNVA value of ≥20/40. The mean monocular CDVA, DCIVA at 80 cm, DCIVA at 66 cm, and DCNVA were −0.09 ± 0.04, 0.12 ± 0.07, 0.21 ± 0.07 and 0.32 ± 0.07 logMAR, respectively. The binocular defocus curve showed good visual acuity at distance and intermediate vision. Conclusions: The isofocal Isopure Serenity IOL can be implanted in eyes with POAG after cataract surgery, achieving a satisfactory visual performance. Our results suggest that this IOL model is a viable option for selected patients with controlled early/moderate POAG and without central visual field involvement diagnosed with cataracts.

Journal of Clinical MedicineVol. 15(14)
Cataract and Refractive Institute of Florida (US)
Openalex Percentile: Top 8%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of Clinical Outcomes of an Isofocal Optic-Design Intraocular Lens with Double C-Loop Haptics in Eyes with Glaucoma — Takayuki Akahoshi · Journal of Clinical Medicine (2026) | TGRS Research Map | TGRS