Following the leaching fronts: Synchrotron (sub)micro-computed tomography for active protective coatings

Model samples of active protective coatings were investigated by synchrotron radiation-based X-ray micro-computed tomography. The resulting 3D images reveal the complex microstructure of the coatings and the progress of the leaching induced by controlled exposure to water between scans. Quantitative analysis of the image data capturing several time steps of the leaching process yields experimental data complementing the commonly used measurement of leached mass. A power law model commonly used to describe leaching was fitted to the leaching front measurements. The influence of the coating composition on the leaching behavior and the leaching front was studied. Interruptions of the exposure affect the leaching behavior unexpectedly strongly. Additional sub-micro images enable moreover to identify and visualize the clusters of interconnected pores generated during the leaching.

Authors

Institutions

Publication Details

Journal
Progress in Organic Coatings
Published
2026-11-17
DOI
https://doi.org/10.1016/j.porgcoat.2026.110720
Citations
1
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.87

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Following the leaching fronts: Synchrotron (sub)micro-computed tomography for active protective coatings

Claudia Redenbach, Peter Visser, Peter Klein, Katja Schladitz et al.
1 citations
Progress in Organic Coatings
Corrosion Behavior and Inhibition
0.87
article

Following the leaching fronts: Synchrotron (sub)micro-computed tomography for active protective coatings

Claudia Redenbach, Peter Visser, Peter Klein, Katja Schladitz, Natalia Konchakova, O Müller, Jelena Zaninović
article en
1 citations

Abstract

Model samples of active protective coatings were investigated by synchrotron radiation-based X-ray micro-computed tomography. The resulting 3D images reveal the complex microstructure of the coatings and the progress of the leaching induced by controlled exposure to water between scans. Quantitative analysis of the image data capturing several time steps of the leaching process yields experimental data complementing the commonly used measurement of leached mass. A power law model commonly used to describe leaching was fitted to the leaching front measurements. The influence of the coating composition on the leaching behavior and the leaching front was studied. Interruptions of the exposure affect the leaching behavior unexpectedly strongly. Additional sub-micro images enable moreover to identify and visualize the clusters of interconnected pores generated during the leaching.

Progress in Organic CoatingsVol. 223
Fraunhofer Institute for Industrial Mathematics (DE), Helmholtz-Zentrum Hereon (DE), Rheinland-Pfälzische Technische Universität Kaiserslautern-Landau (DE), AkzoNobel (Netherlands) (NL)
European Commission
Openalex Percentile: Top 36%
Corrosion Behavior and Inhibition
0.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon