Miri 4-points marker: a low-cost marking device for flanged intrascleral intraocular lens fixation with modified Yamane technique

BACKGROUND: Yamane's flanged intrascleral intraocular lens (IOL) fixation is widely used in eyes without capsular support, but limitations in conventional conjunctival marking may affect surgical precision and consistency. This study compared the clinical outcomes of modified Yamane scleral-fixated IOL implantation using the Miri 4-Points Marker versus Castroviejo calipers, assessing visual outcomes and complications between these two approaches. METHODS: This retrospective cohort study at a single hospital of Malaysia included 44 eyes operated on between 2024 and 2025. Conjunctival markings were made using either the Miri 4-Points Marker or Castroviejo calipers. Two 30-gauge thin-walled needles created right-angled sclerotomies 2 mm posterior to the limbus. IOL haptics were externalized through the needles, cauterized to form a flange, and inserted into scleral tunnels. Descriptive statistics and binary logistic regression were used to assess factors associated with postoperative visual outcomes. RESULTS: Among 44 patients (mean age 64.4 ± 9.7 years, 77.3% male) who underwent intrascleral IOL fixation, the Miri 4-Points Marker was used in 72.7% of cases. Clinical outcomes with the Miri 4-Points Marker were comparable to Castroviejo calipers. Mean postoperative uncorrected visual acuity (UCVA) and corrected distant visual acuity (CDVA) were 0.7 (± 0.4) and 0.4 (± 0.3) logMAR, respectively. At one month postoperatively, 17.2% achieved good UCVA, increasing to 30.8% after excluding ocular comorbidities; 41.4% achieved good CDVA, rising to 46.2% without ocular comorbidities. On univariable analysis, high corneal astigmatism (> 2.5 D) was associated with poorer UCVA across all patients, regardless of Miri 4-Points Marker use (OR = 0.07, 95% CI: 0.01, 0.78, p = 0.03). Multivariable analysis did not identify any independent predictors. CONCLUSIONS: The Miri 4-Points Marker is a feasible and safe adjunct for conjunctival marking in Yamane intrascleral IOL fixation. Observed short-term outcomes were similar to caliper-based marking, although this study's chronological design precludes any conclusion of equivalence.

Authors

Institutions

Publication Details

Journal
BMC Ophthalmology
Published
2026-07-18
DOI
https://doi.org/10.1186/s12886-026-05134-8
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Miri 4-points marker: a low-cost marking device for flanged intrascleral intraocular lens fixation with modified Yamane technique

Jun Fai Yap, Lik Thai Lim, Yong Zheng Wai, Nurhayati Abdul Kadir et al.
BMC Ophthalmology
Intraocular Surgery and Lenses
article

Miri 4-points marker: a low-cost marking device for flanged intrascleral intraocular lens fixation with modified Yamane technique

Jun Fai Yap, Lik Thai Lim, Yong Zheng Wai, Nurhayati Abdul Kadir, Lee Ling Chieng, Wai Seng Chiang, Nurul Afzan MUSTAPHA, Gim Seah CHUAH
article en

Abstract

BACKGROUND: Yamane's flanged intrascleral intraocular lens (IOL) fixation is widely used in eyes without capsular support, but limitations in conventional conjunctival marking may affect surgical precision and consistency. This study compared the clinical outcomes of modified Yamane scleral-fixated IOL implantation using the Miri 4-Points Marker versus Castroviejo calipers, assessing visual outcomes and complications between these two approaches. METHODS: This retrospective cohort study at a single hospital of Malaysia included 44 eyes operated on between 2024 and 2025. Conjunctival markings were made using either the Miri 4-Points Marker or Castroviejo calipers. Two 30-gauge thin-walled needles created right-angled sclerotomies 2 mm posterior to the limbus. IOL haptics were externalized through the needles, cauterized to form a flange, and inserted into scleral tunnels. Descriptive statistics and binary logistic regression were used to assess factors associated with postoperative visual outcomes. RESULTS: Among 44 patients (mean age 64.4 ± 9.7 years, 77.3% male) who underwent intrascleral IOL fixation, the Miri 4-Points Marker was used in 72.7% of cases. Clinical outcomes with the Miri 4-Points Marker were comparable to Castroviejo calipers. Mean postoperative uncorrected visual acuity (UCVA) and corrected distant visual acuity (CDVA) were 0.7 (± 0.4) and 0.4 (± 0.3) logMAR, respectively. At one month postoperatively, 17.2% achieved good UCVA, increasing to 30.8% after excluding ocular comorbidities; 41.4% achieved good CDVA, rising to 46.2% without ocular comorbidities. On univariable analysis, high corneal astigmatism (> 2.5 D) was associated with poorer UCVA across all patients, regardless of Miri 4-Points Marker use (OR = 0.07, 95% CI: 0.01, 0.78, p = 0.03). Multivariable analysis did not identify any independent predictors. CONCLUSIONS: The Miri 4-Points Marker is a feasible and safe adjunct for conjunctival marking in Yamane intrascleral IOL fixation. Observed short-term outcomes were similar to caliper-based marking, although this study's chronological design precludes any conclusion of equivalence.

BMC Ophthalmology
Curtin University Sarawak (MY), Kent Hospital (US), Universiti Malaysia Sarawak (MY), National Institutes of Biotechnology Malaysia (MY), Sabah Forestry Department (MY)
Universiti Malaysia Sarawak
No poverty
Openalex Percentile: Top 6%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.