Enhanced Heat Dissipation of High Voltage Generator Insulation by Reinforcing the Dielectric Strength of Mica Tape

ABSTRACT High voltage generator is an important component of energy power system. Mica tape, as the main component of generator stator bar insulation, has lower thermal conductivity that limits heat dissipation of generator. As voltage increases, heat dissipation problem caused by thickened insulation becomes prominent. Accumulation of heat inside generator affects its stable operation. In this work, polyimide (PI) film filled with hexagonal boron nitride was selected as dielectric reinforcement layer to prepare PI reinforced mica tape with high dielectric strength. Its dielectric strength reached 62.69 kV/mm when the filling amount of 1–3 μm h‐BN was 15 wt%, and its tensile strength and thermal conductivity maintained well. It was found the application of PI reinforced mica tape to the insulation of stator bar resulted in the insulation thickness reduction from 6 to 3.99 mm and a maximum temperature decrease of 3.84°C on the conductor side of the bar. Internal electric field distribution of mica tape was regulated by PI films and the electron migration in PI film was blocked by the in‐plane orientated h‐BN. PI reinforced mica tape will promote the dissipation in generator and help achieve the development of generator towards higher voltage, larger capacity, and higher power density.

Authors

Institutions

Publication Details

Journal
Polymer Composites
Published
2026-07-17
DOI
https://doi.org/10.1002/pc.71428
Primary Topic
Dielectric materials and actuators
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Heat Dissipation of High Voltage Generator Insulation by Reinforcing the Dielectric Strength of Mica Tape

Qiang Fu, Chao Ma, Zhou Yang, Yu Feng et al.
Polymer Composites
Dielectric materials and actuators
article

Enhanced Heat Dissipation of High Voltage Generator Insulation by Reinforcing the Dielectric Strength of Mica Tape

Qiang Fu, Chao Ma, Zhou Yang, Yu Feng, Yuanhang Yao, Dong Yue, Zhe Zhang
article en

Abstract

ABSTRACT High voltage generator is an important component of energy power system. Mica tape, as the main component of generator stator bar insulation, has lower thermal conductivity that limits heat dissipation of generator. As voltage increases, heat dissipation problem caused by thickened insulation becomes prominent. Accumulation of heat inside generator affects its stable operation. In this work, polyimide (PI) film filled with hexagonal boron nitride was selected as dielectric reinforcement layer to prepare PI reinforced mica tape with high dielectric strength. Its dielectric strength reached 62.69 kV/mm when the filling amount of 1–3 μm h‐BN was 15 wt%, and its tensile strength and thermal conductivity maintained well. It was found the application of PI reinforced mica tape to the insulation of stator bar resulted in the insulation thickness reduction from 6 to 3.99 mm and a maximum temperature decrease of 3.84°C on the conductor side of the bar. Internal electric field distribution of mica tape was regulated by PI films and the electron migration in PI film was blocked by the in‐plane orientated h‐BN. PI reinforced mica tape will promote the dissipation in generator and help achieve the development of generator towards higher voltage, larger capacity, and higher power density.

Polymer Composites
Harbin University of Science and Technology (CN), J-Power (Japan) (JP), Harbin Foresty Machinery Institute (CN)
Affordable and clean energy
Openalex Percentile: Top 15%
Dielectric materials and actuators
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhanced Heat Dissipation of High Voltage Generator Insulation by Reinforcing the Dielectric Strength of Mica Tape — Qiang Fu, Chao Ma, et al. · Polymer Composites (2026) | TGRS Research Map | TGRS