The Path of the Light Beam in a Rotating Optical Resonator: An Analysis of the Eisele et al.\ (2009) Experiment

This article analyzes the path of the light beam in one of the cavities (arms) of the rotating optical resonator apparatus described by Antonini et al. (2005) and Eisele et al. (2009), which test the isotropy of the speed of light with extremely high precision. The analysis applies L-ARF (Light – Absolute Reference Framework), based on the principle t = s/c, to calculate the expected resonance frequency in the arm as a function of the apparatus's absolute velocity and orientation, covering all nine combinations of longitudinal and transverse motion relative to the arm's axis. The resulting prediction is compared with the Robertson–Mansouri–Sexl (RMS) test theory and with the experimentally measured result in Eisele et al. (2009). The analysis finds a sharp discrepancy between the L-ARF prediction and the observed null result, and identifies an open question regarding how resonance is maintained under continuous transverse velocity — a question left for future work.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-07-18
DOI
https://doi.org/10.5281/zenodo.21426850
Primary Topic
Geophysics and Sensor Technology
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

The Path of the Light Beam in a Rotating Optical Resonator: An Analysis of the Eisele et al.\ (2009) Experiment

Jan Slowak
Zenodo (CERN European Organization for Nuclear Research)
Geophysics and Sensor Technology
preprint

The Path of the Light Beam in a Rotating Optical Resonator: An Analysis of the Eisele et al.\ (2009) Experiment

Jan Slowak
preprint en

Abstract

This article analyzes the path of the light beam in one of the cavities (arms) of the rotating optical resonator apparatus described by Antonini et al. (2005) and Eisele et al. (2009), which test the isotropy of the speed of light with extremely high precision. The analysis applies L-ARF (Light – Absolute Reference Framework), based on the principle t = s/c, to calculate the expected resonance frequency in the arm as a function of the apparatus's absolute velocity and orientation, covering all nine combinations of longitudinal and transverse motion relative to the arm's axis. The resulting prediction is compared with the Robertson–Mansouri–Sexl (RMS) test theory and with the experimentally measured result in Eisele et al. (2009). The analysis finds a sharp discrepancy between the L-ARF prediction and the observed null result, and identifies an open question regarding how resonance is maintained under continuous transverse velocity — a question left for future work.

Zenodo (CERN European Organization for Nuclear Research)
Geophysics and Sensor Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.