Autoencoder-Based Detection of Nanoplastics in Biological Matrices via Infrared Hyperspectral Imaging

High Resolution Image Download MS PowerPoint Slide Mid-infrared hyperspectral imaging is an emerging tool for the qualitative and quantitative analysis of micro- and nanoplastics (MNPs) and for the characterization of biological tissues and complex matrices. Detecting MNPs in biological materials is of particular interest for assessing toxicological and ecological impacts; however, significant spectral overlap between polymer vibrational bands and those of proteins, lipids, and other biological components complicates identification at low MNP levels. In this work, an autoencoder-based anomaly detection approach is employed to learn the spectral characteristics of biological matrix signals from infrared spectra acquired with quantum cascade laser infrared (QCL-IR) microscopy. Residual-based anomaly mapping preserves chemically meaningful spectral features, enabling heatmap visualization of nanoscale plastic (NP) accumulation in two- and three-dimensional cell culture models. Fully connected (FC), convolutional neural network (CNN) and hybrid (CNN-FC) autoencoder architectures were evaluated, with FC and CNN-FC models providing a balance between accurate biological matrix reconstruction and preservation of NP spectral signatures. The method enabled detection of ∼50 nm plastic particles when present as localized accumulations corresponding to approximately 1% (m/m) of the dried biological material, equivalent to surface density on the order of 10 3 particles/μm 2 . These results demonstrate that residual anomaly detection can extend hyperspectral imaging to visualize nanoscale plastic accumulations in complex biological media at concentrations approaching the instrumental detection limit.

Authors

Institutions

Publication Details

Journal
ACS Measurement Science Au
Published
2026-07-18
DOI
https://doi.org/10.1021/acsmeasuresciau.6c00067
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Autoencoder-Based Detection of Nanoplastics in Biological Matrices via Infrared Hyperspectral Imaging

Shan Zou, Adrian F. Pegoraro, Daniel Prezgot, Sadman Sakib et al.
ACS Measurement Science Au
Microplastics and Plastic Pollution
article

Autoencoder-Based Detection of Nanoplastics in Biological Matrices via Infrared Hyperspectral Imaging

Shan Zou, Adrian F. Pegoraro, Daniel Prezgot, Sadman Sakib, David Corriveau, Maohui Chen
article en

Abstract

High Resolution Image Download MS PowerPoint Slide Mid-infrared hyperspectral imaging is an emerging tool for the qualitative and quantitative analysis of micro- and nanoplastics (MNPs) and for the characterization of biological tissues and complex matrices. Detecting MNPs in biological materials is of particular interest for assessing toxicological and ecological impacts; however, significant spectral overlap between polymer vibrational bands and those of proteins, lipids, and other biological components complicates identification at low MNP levels. In this work, an autoencoder-based anomaly detection approach is employed to learn the spectral characteristics of biological matrix signals from infrared spectra acquired with quantum cascade laser infrared (QCL-IR) microscopy. Residual-based anomaly mapping preserves chemically meaningful spectral features, enabling heatmap visualization of nanoscale plastic (NP) accumulation in two- and three-dimensional cell culture models. Fully connected (FC), convolutional neural network (CNN) and hybrid (CNN-FC) autoencoder architectures were evaluated, with FC and CNN-FC models providing a balance between accurate biological matrix reconstruction and preservation of NP spectral signatures. The method enabled detection of ∼50 nm plastic particles when present as localized accumulations corresponding to approximately 1% (m/m) of the dried biological material, equivalent to surface density on the order of 10 3 particles/μm 2 . These results demonstrate that residual anomaly detection can extend hyperspectral imaging to visualize nanoscale plastic accumulations in complex biological media at concentrations approaching the instrumental detection limit.

ACS Measurement Science Au
National Research Council Canada (CA)
Government of Canada, National Research Council Canada
Life in Land
Openalex Percentile: Top 17%
Microplastics and Plastic Pollution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.