Influence of Artificial Surface Markers on the Accuracy of Full-arch Digital Impressions in Edentulous Arches: An In Vitro Study

Introduction This in vitro study assessed the accuracy of full-arch edentulous impressions obtained via intraoral scanning using various scanning strategies. This study aimed to evaluate whether the addition of surface markers would enhance scan precision in various anatomical regions of edentulous models, particularly on low-feature and smooth surfaces. Methods Sixty scans (30 maxillary and 30 mandibular) were performed using an intraoral scanner across three scanning protocols: unmodified (control), composite-resin, and drawn-line markers. Reference scans were obtained using a laboratory scanner. Scans were evaluated in four anatomical regions: the vestibule, residual ridge, palate/lingual area, and overall surface. Deviations were measured using the root mean square, mean deviation, and standard deviation. Two-way analysis of variance, with Tukey’s post hoc test, was used for the statistical analysis. Results The scanning strategy had no significant effect on the residual ridge area ( p = .918). The jaw type significantly affected the scanning accuracy in all areas ( p < .001), with greater deviations observed in the mandibular scans. Composite-resin and line marker strategies increased the accuracy in the mandibular vestibular and lingual regions. All root mean square error values remained within the clinically acceptable limits, although the numerical differences between the groups were minimal. Conclusion Full-arch intraoral scanning of edentulous models demonstrated clinically acceptable accuracy, within the limitations of this in vitro study. Surface markers did not provide a significant advantage in the maxillary scans but may improve scanning performance in mandibular regions. These findings provide methodological insights into scanning performance on smooth and low-feature surfaces and should be interpreted cautiously when extrapolating to clinical intraoral conditions.

Authors

Institutions

Publication Details

Journal
Journal of Applied Dentistry and Oral Sciences
Published
2026-07-18
DOI
https://doi.org/10.1177/30497418261464802
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Artificial Surface Markers on the Accuracy of Full-arch Digital Impressions in Edentulous Arches: An In Vitro Study

Emel Arslan, Hatice Yemenoğlu
Journal of Applied Dentistry and Oral Sciences
Orthodontics and Dentofacial Orthopedics
article

Influence of Artificial Surface Markers on the Accuracy of Full-arch Digital Impressions in Edentulous Arches: An In Vitro Study

Emel Arslan, Hatice Yemenoğlu
article en

Abstract

Introduction This in vitro study assessed the accuracy of full-arch edentulous impressions obtained via intraoral scanning using various scanning strategies. This study aimed to evaluate whether the addition of surface markers would enhance scan precision in various anatomical regions of edentulous models, particularly on low-feature and smooth surfaces. Methods Sixty scans (30 maxillary and 30 mandibular) were performed using an intraoral scanner across three scanning protocols: unmodified (control), composite-resin, and drawn-line markers. Reference scans were obtained using a laboratory scanner. Scans were evaluated in four anatomical regions: the vestibule, residual ridge, palate/lingual area, and overall surface. Deviations were measured using the root mean square, mean deviation, and standard deviation. Two-way analysis of variance, with Tukey’s post hoc test, was used for the statistical analysis. Results The scanning strategy had no significant effect on the residual ridge area ( p = .918). The jaw type significantly affected the scanning accuracy in all areas ( p < .001), with greater deviations observed in the mandibular scans. Composite-resin and line marker strategies increased the accuracy in the mandibular vestibular and lingual regions. All root mean square error values remained within the clinically acceptable limits, although the numerical differences between the groups were minimal. Conclusion Full-arch intraoral scanning of edentulous models demonstrated clinically acceptable accuracy, within the limitations of this in vitro study. Surface markers did not provide a significant advantage in the maxillary scans but may improve scanning performance in mandibular regions. These findings provide methodological insights into scanning performance on smooth and low-feature surfaces and should be interpreted cautiously when extrapolating to clinical intraoral conditions.

Journal of Applied Dentistry and Oral Sciences
Recep Tayyip Erdoğan University (TR), Bolu Abant İzzet Baysal University (TR)
Openalex Percentile: Top 7%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.