Pristine+™ Everolimus-Eluting Cobalt-Chromium Coronary Stent System: A Prospective, Multicenter Registry

Background: Recent advances in percutaneous coronary interventions (PCIs) have substantially improved clinical outcomes. Generating real-world evidence on the 1-year outcomes of ultrathin-strut drug-eluting stents (DES) remains important, particularly in healthcare settings where cost and accessibility may influence stent selection. Methods: A prospective, single-arm, multicenter registry was conducted to evaluate the 1-year safety and efficacy of an indigenous everolimus-eluting cobalt–chromium stent (EES) (Pristine+™ - Make: Relisys Medical Devices Limited, India) featuring an ultrathin strut (60-µm) design. The primary endpoint was the 1-year incidence of major adverse cardiac event (MACE) defined as a composite of cardiac death (CD), myocardial infarction (MI), and stent thrombosis (ST). Results: The study enrolled 1,088 patients, predominantly male (78.9%). High prevalence of diabetes mellitus (34.7%), hypertension (63.9%), and smoking history (25.7%) was noted. The mean age was 58.6 ± 10.6 years, with 69.9% between 36 and 65 years. A total of 95.9% completed the 1-year follow-up. At 1-year, the Kaplan–Meier incidence of MACE was 2.89% (40 events), comprising 18 CD (1.65%), 13 MI (1.19%), and nine ST (0.83%). All-cause mortality was 2.3% (25 events). One target-vessel myocardial infarction (TV-MI; 0.09%) was reported and no clinically indicated target-lesion revascularization (CI-TLR) events occurred. Conclusion: This study demonstrated favorable 1-year clinical outcomes with Pristine+™, reflected by low rates of MACE and no CI-TLR during the 1-year follow-up. A total of 1,386 Pristine+ EES were implanted in this study.

Authors

Institutions

Publication Details

Journal
Cardiology Research
Published
2026-07-18
DOI
https://doi.org/10.14740/cr2230
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pristine+™ Everolimus-Eluting Cobalt-Chromium Coronary Stent System: A Prospective, Multicenter Registry

Sharma Y P., Rishi Sethi, Prashant Kumar Panda, Ravi Kumar Patnaik et al.
Cardiology Research
Coronary Interventions and Diagnostics
article

Pristine+™ Everolimus-Eluting Cobalt-Chromium Coronary Stent System: A Prospective, Multicenter Registry

Sharma Y P., Rishi Sethi, Prashant Kumar Panda, Ravi Kumar Patnaik, Monika Bhandari, Pravesh Vishwakarma, Supratip Kundu, Pranav Shamraj, Sridhar Kasturi, Parijat Deb Choudhury, Sumanta Chatterjee, Prakash Kumar Hazra, Anil Potdar, Shanivaram Vijay Kumar Reddy, Sheeba George, Akshyaya Pradhan, Pradip Bhowmik
article en

Abstract

Background: Recent advances in percutaneous coronary interventions (PCIs) have substantially improved clinical outcomes. Generating real-world evidence on the 1-year outcomes of ultrathin-strut drug-eluting stents (DES) remains important, particularly in healthcare settings where cost and accessibility may influence stent selection. Methods: A prospective, single-arm, multicenter registry was conducted to evaluate the 1-year safety and efficacy of an indigenous everolimus-eluting cobalt–chromium stent (EES) (Pristine+™ - Make: Relisys Medical Devices Limited, India) featuring an ultrathin strut (60-µm) design. The primary endpoint was the 1-year incidence of major adverse cardiac event (MACE) defined as a composite of cardiac death (CD), myocardial infarction (MI), and stent thrombosis (ST). Results: The study enrolled 1,088 patients, predominantly male (78.9%). High prevalence of diabetes mellitus (34.7%), hypertension (63.9%), and smoking history (25.7%) was noted. The mean age was 58.6 ± 10.6 years, with 69.9% between 36 and 65 years. A total of 95.9% completed the 1-year follow-up. At 1-year, the Kaplan–Meier incidence of MACE was 2.89% (40 events), comprising 18 CD (1.65%), 13 MI (1.19%), and nine ST (0.83%). All-cause mortality was 2.3% (25 events). One target-vessel myocardial infarction (TV-MI; 0.09%) was reported and no clinically indicated target-lesion revascularization (CI-TLR) events occurred. Conclusion: This study demonstrated favorable 1-year clinical outcomes with Pristine+™, reflected by low rates of MACE and no CI-TLR during the 1-year follow-up. A total of 1,386 Pristine+ EES were implanted in this study.

Cardiology ResearchVol. 17(4)
Walsh University (US), King George's Medical University (IN), Sunshine Hospitals (IN), Pain Clinic of India (IN), The Medical Device (United Kingdom) (GB), Manipal Hospital (IN), Post Graduate Institute of Medical Education and Research (IN), AMRI Hospitals (IN)
Good health and well-being
Openalex Percentile: Top 6%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.