Diamond‐Embedded Temperature Control Catheter Enables Faster and More Efficient Cavotricuspid Isthmus Ablation Compared to Contact Force Sensing Catheters

ABSTRACT Background Cavotricuspid isthmus (CTI) ablation is a well‐established treatment for atrial flutter (AFL). The DiamondTemp (DT) catheter provides precise real‐time tissue temperature feedback during radiofrequency (RF) ablation, optimizing energy delivery. While the efficacy of DT in ablation procedures has been demonstrated, its performance in CTI ablation compared with contact force (CF)‐sensing irrigated catheters remains underexplored. This study assessed the efficiency and safety of the DT catheter in CTI ablation. Methods We retrospectively analyzed consecutive patients who underwent CTI ablation between August 2022 and May 2024. Patients were classified into DT and non‐DT groups (TactiFlex, QDOT MICRO, SmartTouch SF, or StablePoint). The primary endpoint was total RF application time. Secondary endpoints included the number of RF applications, total procedure time, acute success rate defined as bidirectional conduction block, and periprocedural complications. All procedures were performed under general anesthesia, using 3D mapping systems. Results A total of 126 patients (mean age 67.4 years, 81.0% male) were included. Bidirectional block was achieved in all patients. Median total RF time was significantly shorter in the DT group compared with the non‐DT group (131.0 [89.0–212.0] vs. 269.0 [196.0–469.0] sec, p < 0.001). The DT group required fewer RF applications ( p < 0.001) and had a shorter total procedure time ( p < 0.001). No complications occurred. Conclusion CTI ablation with the DiamondTemp catheter significantly reduced total RF time and the number of RF applications while maintaining acute procedural success and safety. These findings suggest that the DiamondTemp catheter offers procedural efficiency advantages over conventional CF‐sensing catheters in CTI ablation.

Authors

Institutions

Publication Details

Journal
Journal of Arrhythmia
Published
2026-07-18
DOI
https://doi.org/10.1002/joa3.70427
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diamond‐Embedded Temperature Control Catheter Enables Faster and More Efficient Cavotricuspid Isthmus Ablation Compared to Contact Force Sensing Catheters

Wataru Shinkai, Jun Kishihara, Sho Ogiso, Yuki Arakawa et al.
Journal of Arrhythmia
Cardiac Arrhythmias and Treatments
article

Diamond‐Embedded Temperature Control Catheter Enables Faster and More Efficient Cavotricuspid Isthmus Ablation Compared to Contact Force Sensing Catheters

Wataru Shinkai, Jun Kishihara, Sho Ogiso, Yuki Arakawa, Hidehira Fukaya, Jun Oikawa, Shinichi Niwano, Shuhei Kobayashi, Junya Ako, Megumi Toraiwa, Hironori Nakamura, Naruya Ishizue
article en

Abstract

ABSTRACT Background Cavotricuspid isthmus (CTI) ablation is a well‐established treatment for atrial flutter (AFL). The DiamondTemp (DT) catheter provides precise real‐time tissue temperature feedback during radiofrequency (RF) ablation, optimizing energy delivery. While the efficacy of DT in ablation procedures has been demonstrated, its performance in CTI ablation compared with contact force (CF)‐sensing irrigated catheters remains underexplored. This study assessed the efficiency and safety of the DT catheter in CTI ablation. Methods We retrospectively analyzed consecutive patients who underwent CTI ablation between August 2022 and May 2024. Patients were classified into DT and non‐DT groups (TactiFlex, QDOT MICRO, SmartTouch SF, or StablePoint). The primary endpoint was total RF application time. Secondary endpoints included the number of RF applications, total procedure time, acute success rate defined as bidirectional conduction block, and periprocedural complications. All procedures were performed under general anesthesia, using 3D mapping systems. Results A total of 126 patients (mean age 67.4 years, 81.0% male) were included. Bidirectional block was achieved in all patients. Median total RF time was significantly shorter in the DT group compared with the non‐DT group (131.0 [89.0–212.0] vs. 269.0 [196.0–469.0] sec, p < 0.001). The DT group required fewer RF applications ( p < 0.001) and had a shorter total procedure time ( p < 0.001). No complications occurred. Conclusion CTI ablation with the DiamondTemp catheter significantly reduced total RF time and the number of RF applications while maintaining acute procedural success and safety. These findings suggest that the DiamondTemp catheter offers procedural efficiency advantages over conventional CF‐sensing catheters in CTI ablation.

Journal of ArrhythmiaVol. 42(4)
Kitasato University (JP)
Affordable and clean energy
Openalex Percentile: Top 8%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.