Parametric study of monolithic gas–solid heat exchanger performance

Monoliths are used as substrates in structured catalytic reactors, as volumetric receivers in solar thermal power plants, and as gas-solid heat exchangers in Ultra-High Temperature Thermal Energy Storage systems. A numerical model for the steady-state heat transfer rate, mass flow rate distribution, and pressure loss of monolithic gas-solid heat exchangers is proposed, verified and validated in an earlier work. The flow along each duct is assumed to be one-dimensional and compressible. In the solid, the non-linear finite element method is used to solve the three-dimensional heat conduction equation. In this paper, the model is used to perform seven geometric parameter sweeps for a heat exchanger operating in an Ultra-High Temperature Thermal Energy Storage system. The heat exchanger transfers heat from the lateral surface of the monolith to a working gas flowing through the ducts. Using the sweeps, the effect that monolith geometry, monolith thermal conductivity, and heat exchanger mass flow rate have on heat exchanger performance is explored. Two duct placement patterns are considered — a legged pattern in which the duct spacing is non-uniform, and a uniformly spaced hexagonal pattern. It is observed that the ratio of heat exchanger heat transfer coefficient to mean monolith thermal conductivity can be higher in monoliths with a lower mean thermal conductivity. The legged pattern is able to give a heat exchanger Nusselt number that is higher than that of the hexagonal pattern by a factor of 1.86, albeit with a pressure loss that is higher by a factor of 2.02. A heat exchanger with desirable performance is selected from the seven sweeps. This heat exchanger has a maximally spaced hexagonal pattern, an effectiveness of 0.975, a Nusselt number of 894, and a relative pressure loss of 1.18e-2. It is estimated that this heat exchanger would occupy 0.018% of the storage medium volume, for a grid-scale storage system.

Authors

Publication Details

Journal
Applied Thermal Engineering
Published
2026-11-19
DOI
https://doi.org/10.1016/j.applthermaleng.2026.133990
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Parametric study of monolithic gas–solid heat exchanger performance

Aldwyn Eyres, Adam Robinson
Applied Thermal Engineering
Heat Transfer and Optimization
article

Parametric study of monolithic gas–solid heat exchanger performance

Aldwyn Eyres, Adam Robinson
article en

Abstract

Monoliths are used as substrates in structured catalytic reactors, as volumetric receivers in solar thermal power plants, and as gas-solid heat exchangers in Ultra-High Temperature Thermal Energy Storage systems. A numerical model for the steady-state heat transfer rate, mass flow rate distribution, and pressure loss of monolithic gas-solid heat exchangers is proposed, verified and validated in an earlier work. The flow along each duct is assumed to be one-dimensional and compressible. In the solid, the non-linear finite element method is used to solve the three-dimensional heat conduction equation. In this paper, the model is used to perform seven geometric parameter sweeps for a heat exchanger operating in an Ultra-High Temperature Thermal Energy Storage system. The heat exchanger transfers heat from the lateral surface of the monolith to a working gas flowing through the ducts. Using the sweeps, the effect that monolith geometry, monolith thermal conductivity, and heat exchanger mass flow rate have on heat exchanger performance is explored. Two duct placement patterns are considered — a legged pattern in which the duct spacing is non-uniform, and a uniformly spaced hexagonal pattern. It is observed that the ratio of heat exchanger heat transfer coefficient to mean monolith thermal conductivity can be higher in monoliths with a lower mean thermal conductivity. The legged pattern is able to give a heat exchanger Nusselt number that is higher than that of the hexagonal pattern by a factor of 1.86, albeit with a pressure loss that is higher by a factor of 2.02. A heat exchanger with desirable performance is selected from the seven sweeps. This heat exchanger has a maximally spaced hexagonal pattern, an effectiveness of 0.975, a Nusselt number of 894, and a relative pressure loss of 1.18e-2. It is estimated that this heat exchanger would occupy 0.018% of the storage medium volume, for a grid-scale storage system.

Applied Thermal EngineeringVol. 311
Affordable and clean energy
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon