Utility of Photon Counting Detector CT Angiography for Detecting Spinal Arteriovenous Fistulas

Photon counting detector CT is a relatively nascent technology with numerous developing applications in neuroradiology. Its novel x-ray detection mechanism confers several advantages, including higher spatial resolution, inherent spectral sensitivity, and improved contrast-to-noise ratio. These have been shown to have benefits in vascular imaging. One potential vascular application is spinal photon counting CT angiography for detection and characterization of spinal arteriovenous fistulas, a treatable cause of myelopathy. In this clinical report, we performed a retrospective case series from two institutions, identifying eight patients who underwent a photon counting spinal CT angiogram for the purposes of detecting an arteriovenous fistula. We assessed the diagnostic value of this technique and compared two different reconstructions in our protocol. We found that a site of arteriovenous fistula was successfully localized in all eight patients, and this was confirmed on subsequent surgery or conventional angiography. In all cases, these fistulas were best seen on 0.2 mm low-energy threshold reconstructions.

Authors

Institutions

Publication Details

Journal
American Journal of Neuroradiology
Published
2026-07-17
DOI
https://doi.org/10.3174/ajnr.a9533
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utility of Photon Counting Detector CT Angiography for Detecting Spinal Arteriovenous Fistulas

Jessica L. Houk, Felix E. Diehn, Timothy J. Amrhein, Peter G. Kranz et al.
American Journal of Neuroradiology
Advanced X-ray and CT Imaging
article

Utility of Photon Counting Detector CT Angiography for Detecting Spinal Arteriovenous Fistulas

Jessica L. Houk, Felix E. Diehn, Timothy J. Amrhein, Peter G. Kranz, Erik F. Hauck, Michelle L. Kodet, Girish Bathla, Ajay A. Madhavan, Cynthia H. McCollough
article en

Abstract

Photon counting detector CT is a relatively nascent technology with numerous developing applications in neuroradiology. Its novel x-ray detection mechanism confers several advantages, including higher spatial resolution, inherent spectral sensitivity, and improved contrast-to-noise ratio. These have been shown to have benefits in vascular imaging. One potential vascular application is spinal photon counting CT angiography for detection and characterization of spinal arteriovenous fistulas, a treatable cause of myelopathy. In this clinical report, we performed a retrospective case series from two institutions, identifying eight patients who underwent a photon counting spinal CT angiogram for the purposes of detecting an arteriovenous fistula. We assessed the diagnostic value of this technique and compared two different reconstructions in our protocol. We found that a site of arteriovenous fistula was successfully localized in all eight patients, and this was confirmed on subsequent surgery or conventional angiography. In all cases, these fistulas were best seen on 0.2 mm low-energy threshold reconstructions.

American Journal of Neuroradiology
Mayo Clinic (US)
Good health and well-being
Openalex Percentile: Top 15%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.