Axial Length and Optimal Spectacle Correction in Myopia - A Paraxial ABCD-Matrix Simulation Using the Gullstrand-Emsley Schematic Eye

This study models the human eye using the Gullstrand–Emsley schematic eye and ABCD ray transfer matrices to identify the prescription power that minimises retinal blur as a function of axial length. A cascade of 10 optical elements was constructed and a single paraxial ray was traced through it. Axial lengths from 22 mm to 30 mm and corrective lens powers from −14 D to +2 D were simulated using Python. The data demonstrated a strong negative linear correlation between axial length and optimal corrective lens power (R² = 0.9999). Optimal correction reduced retinal blur to approximately 0 mm, demonstrating that ABCD matrices can simulate refractive correction in myopic eyes and provide a transparent illustration of axial-length-based refraction.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-07-17
DOI
https://doi.org/10.5281/zenodo.21400044
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Axial Length and Optimal Spectacle Correction in Myopia - A Paraxial ABCD-Matrix Simulation Using the Gullstrand-Emsley Schematic Eye

Akshara Agrawal
Zenodo (CERN European Organization for Nuclear Research)
Ophthalmology and Visual Impairment Studies
preprint

Axial Length and Optimal Spectacle Correction in Myopia - A Paraxial ABCD-Matrix Simulation Using the Gullstrand-Emsley Schematic Eye

Akshara Agrawal
preprint en

Abstract

This study models the human eye using the Gullstrand–Emsley schematic eye and ABCD ray transfer matrices to identify the prescription power that minimises retinal blur as a function of axial length. A cascade of 10 optical elements was constructed and a single paraxial ray was traced through it. Axial lengths from 22 mm to 30 mm and corrective lens powers from −14 D to +2 D were simulated using Python. The data demonstrated a strong negative linear correlation between axial length and optimal corrective lens power (R² = 0.9999). Optimal correction reduced retinal blur to approximately 0 mm, demonstrating that ABCD matrices can simulate refractive correction in myopic eyes and provide a transparent illustration of axial-length-based refraction.

Zenodo (CERN European Organization for Nuclear Research)
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.