Toward Silica‐Free Compliance: A Low‐Viscosity Sample Pretreatment Methodology for Crystalline Quartz Quantification in Viscous Pastes

ABSTRACT Crystalline quartz, the most common crystalline silica polymorph, is widely found in industrial products. It is of high regulatory relevance, because its fine fraction, a form of respirable crystalline silica, is classified as an occupational carcinogen, with product‐content thresholds (e.g., 0.1% (w/w) in the European Union) and stringent occupational exposure limits. Since larger size fractions can be reduced to the fine one during work processes and use, a silica‐free approach should be pursued, driving the need for accurate and sensitive quantification of crystalline quartz, even in complex matrices. X‐ray diffraction (XRD) is a reference technique for selective quartz determination; however, paraffin‐rich abrasive and polishing pastes pose a major analytical challenge due to their dense, viscous rheology, which prevents homogeneous incorporation of crystalline internal standards or spikes required by validated quantitative XRD approaches (e.g., EN 13925, EN 17289). Here, we develop and optimize a low‐viscosity sample pretreatment, termed low‐viscosity doping (LVD), to overcome matrix‐driven inhomogeneity. LVD mitigates rheological constraints, enables uniform internal‐standard distribution, and improves the reliability of quantitative XRD. Using LVD, crystalline quartz mass fractions were determined with good accuracy and repeatability at levels well below the 0.1% product threshold. The proposed workflow is standardized, time‐efficient, and compatible with modern benchtop diffractometers, potentially paving the way for a standard aimed at enhancing safety compliance and risk mitigation in the abrasive and polishing products industry.

Authors

Institutions

Publication Details

Journal
X-Ray Spectrometry
Published
2026-07-17
DOI
https://doi.org/10.1002/xrs.70128
Primary Topic
Polymer Nanocomposites and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Toward Silica‐Free Compliance: A Low‐Viscosity Sample Pretreatment Methodology for Crystalline Quartz Quantification in Viscous Pastes

M.C. Buoso, Giacomo Siviero, Giulia Moro, Diego Andreola
X-Ray Spectrometry
Polymer Nanocomposites and Properties
article

Toward Silica‐Free Compliance: A Low‐Viscosity Sample Pretreatment Methodology for Crystalline Quartz Quantification in Viscous Pastes

M.C. Buoso, Giacomo Siviero, Giulia Moro, Diego Andreola
article en

Abstract

ABSTRACT Crystalline quartz, the most common crystalline silica polymorph, is widely found in industrial products. It is of high regulatory relevance, because its fine fraction, a form of respirable crystalline silica, is classified as an occupational carcinogen, with product‐content thresholds (e.g., 0.1% (w/w) in the European Union) and stringent occupational exposure limits. Since larger size fractions can be reduced to the fine one during work processes and use, a silica‐free approach should be pursued, driving the need for accurate and sensitive quantification of crystalline quartz, even in complex matrices. X‐ray diffraction (XRD) is a reference technique for selective quartz determination; however, paraffin‐rich abrasive and polishing pastes pose a major analytical challenge due to their dense, viscous rheology, which prevents homogeneous incorporation of crystalline internal standards or spikes required by validated quantitative XRD approaches (e.g., EN 13925, EN 17289). Here, we develop and optimize a low‐viscosity sample pretreatment, termed low‐viscosity doping (LVD), to overcome matrix‐driven inhomogeneity. LVD mitigates rheological constraints, enables uniform internal‐standard distribution, and improves the reliability of quantitative XRD. Using LVD, crystalline quartz mass fractions were determined with good accuracy and repeatability at levels well below the 0.1% product threshold. The proposed workflow is standardized, time‐efficient, and compatible with modern benchtop diffractometers, potentially paving the way for a standard aimed at enhancing safety compliance and risk mitigation in the abrasive and polishing products industry.

X-Ray Spectrometry
Ca' Foscari University of Venice (IT), Gruppo Italiano per lo Studio dei Carcinomi dell’Apparato Digerente (IT), Ospedale San Bassiano (IT)
Industry, innovation and infrastructure
Openalex Percentile: Top 17%
Polymer Nanocomposites and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Toward Silica‐Free Compliance: A Low‐Viscosity Sample Pretreatment Methodology for Crystalline Quartz Quantification in Viscous Pastes — M.C. Buoso, Giacomo Siviero, et al. · X-Ray Spectrometry (2026) | TGRS Research Map | TGRS