Comparison of breath hold and abdominal compression for liver SABR on C-arm Linac and MR Linac: A single institution retrospective planning study

BACKGROUND: Respiratory motion is a challenge for accurate stereotactic ablative radiotherapy (SABR) to the liver. This study compares the dosimetric impact of abdominal compression (AC), breath hold (BH) and free-breathing (FB) strategies for liver SABR on conventional C-arm linear accelerators (Linacs) and magnetic resonance Linacs (MR Linacs). METHODS: Five patients undergoing liver SABR were imaged using T2-weighted turbo-spin echo and cine-MRI with FB and AC, and mDixon with BH. The gross tumour volume (GTV) was expanded based on quantified motion to generate the internal target volume (ITV) for FB and AC, and 5 mm PTV margin added. Plans were generated for FB, AC, and BH, prescribing 4000 cGy in 5 fractions to the planning target volume (PTV). Target coverage and organ at risk (OARs) doses were assessed. RESULTS: BH plans provided superior target coverage and minimized dose to most OARs across both platforms. Median GTVexhale size was 17.77 cc, with median PTV sizes of 51.96 cc (BH), 89.99 cc (AC), and 79.59 cc (FB). On C-arm Linac, BH achieved highest mean Dmin (2969 cGy) and D95% (3888 cGy). On MR Linac, BH also showed highest mean Dmin (3056 cGy) and D95% (3916 cGy). AC and FB plans resulted in higher OAR doses. CONCLUSION: All evaluated motion management strategies produced acceptable plans, but BH offered the best overall target coverage and reduced OAR doses on both platforms. Although differences between strategies are overall small. Motion management strategies should therefore be selected on a patient-by-patient basis based on patient acceptability and dosimetric benefit.

Authors

Institutions

Publication Details

Journal
Physica Medica
Published
2026-07-18
DOI
https://doi.org/10.1016/j.ejmp.2026.105887
Primary Topic
Abdominal Surgery and Complications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of breath hold and abdominal compression for liver SABR on C-arm Linac and MR Linac: A single institution retrospective planning study

Alan McWilliam, C. Eccles, Ananya Choudhury, Mairéad Daly et al.
Physica Medica
Abdominal Surgery and Complications
article

Comparison of breath hold and abdominal compression for liver SABR on C-arm Linac and MR Linac: A single institution retrospective planning study

Alan McWilliam, C. Eccles, Ananya Choudhury, Mairéad Daly, Ganesh Radhakrishna
article en

Abstract

BACKGROUND: Respiratory motion is a challenge for accurate stereotactic ablative radiotherapy (SABR) to the liver. This study compares the dosimetric impact of abdominal compression (AC), breath hold (BH) and free-breathing (FB) strategies for liver SABR on conventional C-arm linear accelerators (Linacs) and magnetic resonance Linacs (MR Linacs). METHODS: Five patients undergoing liver SABR were imaged using T2-weighted turbo-spin echo and cine-MRI with FB and AC, and mDixon with BH. The gross tumour volume (GTV) was expanded based on quantified motion to generate the internal target volume (ITV) for FB and AC, and 5 mm PTV margin added. Plans were generated for FB, AC, and BH, prescribing 4000 cGy in 5 fractions to the planning target volume (PTV). Target coverage and organ at risk (OARs) doses were assessed. RESULTS: BH plans provided superior target coverage and minimized dose to most OARs across both platforms. Median GTVexhale size was 17.77 cc, with median PTV sizes of 51.96 cc (BH), 89.99 cc (AC), and 79.59 cc (FB). On C-arm Linac, BH achieved highest mean Dmin (2969 cGy) and D95% (3888 cGy). On MR Linac, BH also showed highest mean Dmin (3056 cGy) and D95% (3916 cGy). AC and FB plans resulted in higher OAR doses. CONCLUSION: All evaluated motion management strategies produced acceptable plans, but BH offered the best overall target coverage and reduced OAR doses on both platforms. Although differences between strategies are overall small. Motion management strategies should therefore be selected on a patient-by-patient basis based on patient acceptability and dosimetric benefit.

Physica MedicaVol. 148
University of Manchester (GB), Cancer Research UK Manchester Institute (GB), The Christie NHS Foundation Trust (GB)
Christie Charity, Cancer Research UK, Manchester Biomedical Research Centre
Sustainable cities and communities
Openalex Percentile: Top 9%
Abdominal Surgery and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.