Haidarian Friday paper: Stress shield in dental implantology, the disguised culprit. Another introduction to implant abutment connection classification and the need to leave the platform switching concept behind and move forward

Platform switching is deceiving backwardening concepts in the implant dentistry field. It distracts us from the two major issues: corrosion and stress shield. Evaluation of the abutment-implant connection performance depending on the cone angle is the only true, correct, right, valid, and sound way. Stress shield is one of the major causes of bone osteolysis around metallic implants due to the resultant disturbed stress distribution between the different parts of the implant. Stress shield is simply the loss of load during load transfer. In this paper, we want to approach this issue of quitting platform switch umbrella of unawareness and go forward for cone evaluation depending on cone angle, reviewing it from a mechanical perspective

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-07-17
DOI
https://doi.org/10.5281/zenodo.21416561
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Haidarian Friday paper: Stress shield in dental implantology, the disguised culprit. Another introduction to implant abutment connection classification and the need to leave the platform switching concept behind and move forward

Mohammed Mohammed Zahid S.
Zenodo (CERN European Organization for Nuclear Research)
Dental Implant Techniques and Outcomes
article

Haidarian Friday paper: Stress shield in dental implantology, the disguised culprit. Another introduction to implant abutment connection classification and the need to leave the platform switching concept behind and move forward

Mohammed Mohammed Zahid S.
article en

Abstract

Platform switching is deceiving backwardening concepts in the implant dentistry field. It distracts us from the two major issues: corrosion and stress shield. Evaluation of the abutment-implant connection performance depending on the cone angle is the only true, correct, right, valid, and sound way. Stress shield is one of the major causes of bone osteolysis around metallic implants due to the resultant disturbed stress distribution between the different parts of the implant. Stress shield is simply the loss of load during load transfer. In this paper, we want to approach this issue of quitting platform switch umbrella of unawareness and go forward for cone evaluation depending on cone angle, reviewing it from a mechanical perspective

Zenodo (CERN European Organization for Nuclear Research)
University Teaching Hospital (ZM)
Openalex Percentile: Top 6%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Haidarian Friday paper: Stress shield in dental implantology, the disguised culprit. Another introduction to implant abutment connection classification and the need to leave the platform switching concept behind and move forward — Mohammed Mohammed Zahid S. · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS