Pseudo-Pulseless Electrical Activity With Anaphylaxis in a Pediatric Surgical Patient: A Case Report

Pseudo-pulseless electrical activity (p-PEA) is a clinical condition where cardiac output drops severely enough to produce a non-palpable pulse in the setting of organized electrical activity of the heart, but imaging or monitors display evidence of cardiac motion. It may be seen in shock states such as anaphylactic shock. We describe a case where a previously healthy teenage patient presenting for operative removal of orthopedic hardware developed p-PEA after anaphylaxis to antibiotics. Despite loss of pulses and severe mottling of the skin, the patient’s pulse oximetry (plethysmography) and capnometry (measurement of end-tidal carbon dioxide) displayed visually normal, reassuring waveforms. The condition responded to chest compressions and administration of epinephrine and vasopressin; the patient was ultimately able to be discharged home on postoperative day (POD) 2. Prompt recognition, diagnosis, and clinical management of p-PEA and anaphylaxis are key to good patient outcomes. Epinephrine is the mainstay of treatment for anaphylactic reactions and is indicated during cardiopulmonary resuscitation (CPR) for p-PEA.

Authors

Publication Details

Journal
Cureus
Published
2026-07-17
DOI
https://doi.org/10.7759/cureus.112837
Primary Topic
Food Allergy and Anaphylaxis Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pseudo-Pulseless Electrical Activity With Anaphylaxis in a Pediatric Surgical Patient: A Case Report

Martha O. Herbst, Timothy W. Morris, Joshua Stopak, Alexandria R Nicolaus
Cureus
Food Allergy and Anaphylaxis Research
article

Pseudo-Pulseless Electrical Activity With Anaphylaxis in a Pediatric Surgical Patient: A Case Report

Martha O. Herbst, Timothy W. Morris, Joshua Stopak, Alexandria R Nicolaus
article en

Abstract

Pseudo-pulseless electrical activity (p-PEA) is a clinical condition where cardiac output drops severely enough to produce a non-palpable pulse in the setting of organized electrical activity of the heart, but imaging or monitors display evidence of cardiac motion. It may be seen in shock states such as anaphylactic shock. We describe a case where a previously healthy teenage patient presenting for operative removal of orthopedic hardware developed p-PEA after anaphylaxis to antibiotics. Despite loss of pulses and severe mottling of the skin, the patient’s pulse oximetry (plethysmography) and capnometry (measurement of end-tidal carbon dioxide) displayed visually normal, reassuring waveforms. The condition responded to chest compressions and administration of epinephrine and vasopressin; the patient was ultimately able to be discharged home on postoperative day (POD) 2. Prompt recognition, diagnosis, and clinical management of p-PEA and anaphylaxis are key to good patient outcomes. Epinephrine is the mainstay of treatment for anaphylactic reactions and is indicated during cardiopulmonary resuscitation (CPR) for p-PEA.

Cureus
Clean water and sanitation, Life below water
Openalex Percentile: Top 10%
Food Allergy and Anaphylaxis Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pseudo-Pulseless Electrical Activity With Anaphylaxis in a Pediatric Surgical Patient: A Case Report — Martha O. Herbst, Timothy W. Morris, et al. · Cureus (2026) | TGRS Research Map | TGRS