Calibration-free whole-brain CEST imaging at 7T with parallel transmit PUlse design for Satura'on Homogeneity u'lizing Universal Pulses (PUSHUP)

Purpose: CEST measurements at UHF su↵er from strong saturation inhomogeneity. Retrospective correction of this inhomogeneity is possible to some extent, but requires a time-consuming repetition of the measurement. Here, we propose a calibration-free parallel transmit (pTx)-based saturation scheme that homogenizes the saturation over the imaging volume, which we call PUSHUP.Theory : Magnetization transfer effects depend on the saturation Brms1 . PUSHUP homogenizes the saturation Brms1 by using multiple saturation pulses with alternating B1-shims. Using a database of B1 maps, universal pulses are calculated that remove the necessity of time-consuming, subjectbased pulse calculation during the measurement.Methods: PUSHUP was combined with a whole-brain 3D-EPI readout. Two PUSHUP saturation modules were calculated by either applying whole-brain or cerebellum masks to the database maps. The saturation homogeneity and the group mean CEST amplitudes were calculated for di↵erent B1-correction methods and were compared to circular polarized (CP) saturation in 5 healthy volunteers using an 8-channel transmit coil at 7 Tesla.Results: In contrast to CP saturation, where accurate CEST maps were impossible to obtain in the cerebellum, even with extensive B1-correction, PUSHUP CEST maps were artifact-free throughout the whole brain. A 1-point retrospective B1-correction, that does not need repeated measurements, suciently removed the effect of residual saturation inhomogeneity.Conclusion : The presented method allows for homogeneous whole-brain CEST imaging at 7 Tesla without the need of a repetition-based B1-correction or online pulse calculation. With the fast 3D-EPI readout, whole-brain CEST imaging with 45 saturation offsets is possible at 1.6 mm resolution in under 4 minutes.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-07-17
DOI
https://doi.org/10.5281/zenodo.21410117
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration-free whole-brain CEST imaging at 7T with parallel transmit PUlse design for Satura'on Homogeneity u'lizing Universal Pulses (PUSHUP)

Yannik Völzke, Suzan Akbey, Vincent Gras, Nicolas Boulant et al.
Zenodo (CERN European Organization for Nuclear Research)
Advanced MRI Techniques and Applications
article

Calibration-free whole-brain CEST imaging at 7T with parallel transmit PUlse design for Satura'on Homogeneity u'lizing Universal Pulses (PUSHUP)

Yannik Völzke, Suzan Akbey, Vincent Gras, Nicolas Boulant, Moritz Zaiß, Tony Stoecker, Eberhard Pracht, Daniel Löwen
article en

Abstract

Purpose: CEST measurements at UHF su↵er from strong saturation inhomogeneity. Retrospective correction of this inhomogeneity is possible to some extent, but requires a time-consuming repetition of the measurement. Here, we propose a calibration-free parallel transmit (pTx)-based saturation scheme that homogenizes the saturation over the imaging volume, which we call PUSHUP.Theory : Magnetization transfer effects depend on the saturation Brms1 . PUSHUP homogenizes the saturation Brms1 by using multiple saturation pulses with alternating B1-shims. Using a database of B1 maps, universal pulses are calculated that remove the necessity of time-consuming, subjectbased pulse calculation during the measurement.Methods: PUSHUP was combined with a whole-brain 3D-EPI readout. Two PUSHUP saturation modules were calculated by either applying whole-brain or cerebellum masks to the database maps. The saturation homogeneity and the group mean CEST amplitudes were calculated for di↵erent B1-correction methods and were compared to circular polarized (CP) saturation in 5 healthy volunteers using an 8-channel transmit coil at 7 Tesla.Results: In contrast to CP saturation, where accurate CEST maps were impossible to obtain in the cerebellum, even with extensive B1-correction, PUSHUP CEST maps were artifact-free throughout the whole brain. A 1-point retrospective B1-correction, that does not need repeated measurements, suciently removed the effect of residual saturation inhomogeneity.Conclusion : The presented method allows for homogeneous whole-brain CEST imaging at 7 Tesla without the need of a repetition-based B1-correction or online pulse calculation. With the fast 3D-EPI readout, whole-brain CEST imaging with 45 saturation offsets is possible at 1.6 mm resolution in under 4 minutes.

Zenodo (CERN European Organization for Nuclear Research)
University of Bonn (DE), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), German Center for Neurodegenerative Diseases (DE), CEA Paris-Saclay (FR)
European Commission
Openalex Percentile: Top 8%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.