Feasibility of a Fully Covered Self-Expandable Metal Stent with a Central Waist and a Long Removal String for Management of Malignant Distal Biliary Obstruction: A Multicenter Prospective Pilot Study

Background/Objectives: A fully covered self-expandable metal stent (FCSEMS) with a central waist and long retrieval string has recently been introduced for benign biliary strictures; however, its role in malignant biliary obstruction (MBO) remains unclear. This prospective, multicenter study evaluated the feasibility of palliation for unresectable distal MBO. Methods: Between April 2022 and March 2023, patients with extrahepatic MBO were enrolled across six tertiary referral centers. The FCSEMS was a silicone-covered, cross-wired nitinol stent with an anti-migration central waist 2 mm narrower than both ends, three radiopaque markers, and a 10 cm retrieval string. Stent-related outcomes and adverse events were analyzed. Results: Both technical and clinical success rates were 100% (46/46). The median stent patency and survival times were 251 and 360 days, respectively. Stent dysfunction occurred in 18 patients (39.1%), including 10 with migration and 8 with occlusion. Stent migration was observed exclusively in the transpapillary stenting group and showed no significant association with stricture length, stent-bending angle, or the ratio of stent lengths above and below the maximal bending point. All the occluded stents were successfully removed. Early non-recurrent biliary obstruction (RBO) adverse events occurred in five patients (three with pancreatitis, one with bleeding, one with cholecystitis), whereas late non-RBO events were reported in three patients (two with cholecystitis, one with cholangitis). Conclusions: An FCSEMS with a central waist and retrieval string is feasible for the palliation of unresectable distal MBO. Optimization of the mechanical properties is warranted to minimize migration.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-07-17
DOI
https://doi.org/10.3390/jcm15145612
Primary Topic
Gallbladder and Bile Duct Disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of a Fully Covered Self-Expandable Metal Stent with a Central Waist and a Long Removal String for Management of Malignant Distal Biliary Obstruction: A Multicenter Prospective Pilot Study

Min Jae Yang, Sung Ill Jang, Kwang Bum Cho, Seok Jeong et al.
Journal of Clinical Medicine
Gallbladder and Bile Duct Disorders
article

Feasibility of a Fully Covered Self-Expandable Metal Stent with a Central Waist and a Long Removal String for Management of Malignant Distal Biliary Obstruction: A Multicenter Prospective Pilot Study

Min Jae Yang, Sung Ill Jang, Kwang Bum Cho, Seok Jeong, Dong Kee Jang, D Lee
article en

Abstract

Background/Objectives: A fully covered self-expandable metal stent (FCSEMS) with a central waist and long retrieval string has recently been introduced for benign biliary strictures; however, its role in malignant biliary obstruction (MBO) remains unclear. This prospective, multicenter study evaluated the feasibility of palliation for unresectable distal MBO. Methods: Between April 2022 and March 2023, patients with extrahepatic MBO were enrolled across six tertiary referral centers. The FCSEMS was a silicone-covered, cross-wired nitinol stent with an anti-migration central waist 2 mm narrower than both ends, three radiopaque markers, and a 10 cm retrieval string. Stent-related outcomes and adverse events were analyzed. Results: Both technical and clinical success rates were 100% (46/46). The median stent patency and survival times were 251 and 360 days, respectively. Stent dysfunction occurred in 18 patients (39.1%), including 10 with migration and 8 with occlusion. Stent migration was observed exclusively in the transpapillary stenting group and showed no significant association with stricture length, stent-bending angle, or the ratio of stent lengths above and below the maximal bending point. All the occluded stents were successfully removed. Early non-recurrent biliary obstruction (RBO) adverse events occurred in five patients (three with pancreatitis, one with bleeding, one with cholecystitis), whereas late non-RBO events were reported in three patients (two with cholecystitis, one with cholangitis). Conclusions: An FCSEMS with a central waist and retrieval string is feasible for the palliation of unresectable distal MBO. Optimization of the mechanical properties is warranted to minimize migration.

Journal of Clinical MedicineVol. 15(14)
Samsung Medical Center (KR), Kyungpook National University (KR), Keimyung University Dongsan Medical Center (KR), Gangnam Severance Hospital (KR), Inha University Hospital (KR), Keimyung University (KR), Ajou University (KR), Sungkyunkwan University (KR)
Korea Health Industry Development Institute, National Research Foundation of Korea
Reduced inequalities
Openalex Percentile: Top 9%
Gallbladder and Bile Duct Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.