Quality Cost A* Path Planning for Multi-Sensor Fusion in Corridor Smoke Scenarios

Indoor fire smoke degrades visible-light cameras and near-infrared Lidar through wavelength-dependent absorption and scattering, threatening robotic navigation safety. Existing path planners either ignore sensor degradation or rely on empirical penalties lacking a physical basis. To address these issues, this paper proposes Quality Cost A* (QC-A*), which maps Fire Dynamics Simulator (FDS) visibility fields to sensor perception quality via the Koschmieder and Beer–Lambert physical laws, embedding a cost function that drives paths away from high-attenuation regions. A multi-sensor fusion layer provides fault tolerance under sensor-specific failure conditions. The method is validated through FDS-based simulations across four smoke scenarios in a 20 m × 6 m corridor with 21 obstacles, using 50 start–goal pairs per scenario. Perception quality derives from Beer–Lambert optical transmittance, while the hazard-zone proportion quantifies path segments with visibility below 5 m. Across the Symmetric and Asymmetric scenarios, QC-A* reduces the low-visibility hazard-zone proportion from 40.7% to 19.6% and improves worst-case perception quality from 0.067 to 0.177, with a 15.3% path length increase, while remaining close to traditional A* in light-smoke conditions. Under constructed sensor failure tests, QC-A* maintains a 96–100% planning success rate versus 48% for Camera-Only and 70% for Lidar-Only. QC-A* shifts sensor degradation modeling from empirical penalty to physical mechanism, achieving a favorable safety–efficiency balance prioritizing perceptual safety, and provides an interpretable, generalizable framework for robotic fire-environment path planning.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-07-17
DOI
https://doi.org/10.3390/s26144530
Primary Topic
Fire Detection and Safety Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quality Cost A* Path Planning for Multi-Sensor Fusion in Corridor Smoke Scenarios

L Q Liu, X LIU, Yang Feng, Yuanhao Sun et al.
Sensors
Fire Detection and Safety Systems
article

Quality Cost A* Path Planning for Multi-Sensor Fusion in Corridor Smoke Scenarios

L Q Liu, X LIU, Yang Feng, Yuanhao Sun, Bo Zhang, Ben Wang, Hua Xia, Shuai Zhu, Hao Chen
article en

Abstract

Indoor fire smoke degrades visible-light cameras and near-infrared Lidar through wavelength-dependent absorption and scattering, threatening robotic navigation safety. Existing path planners either ignore sensor degradation or rely on empirical penalties lacking a physical basis. To address these issues, this paper proposes Quality Cost A* (QC-A*), which maps Fire Dynamics Simulator (FDS) visibility fields to sensor perception quality via the Koschmieder and Beer–Lambert physical laws, embedding a cost function that drives paths away from high-attenuation regions. A multi-sensor fusion layer provides fault tolerance under sensor-specific failure conditions. The method is validated through FDS-based simulations across four smoke scenarios in a 20 m × 6 m corridor with 21 obstacles, using 50 start–goal pairs per scenario. Perception quality derives from Beer–Lambert optical transmittance, while the hazard-zone proportion quantifies path segments with visibility below 5 m. Across the Symmetric and Asymmetric scenarios, QC-A* reduces the low-visibility hazard-zone proportion from 40.7% to 19.6% and improves worst-case perception quality from 0.067 to 0.177, with a 15.3% path length increase, while remaining close to traditional A* in light-smoke conditions. Under constructed sensor failure tests, QC-A* maintains a 96–100% planning success rate versus 48% for Camera-Only and 70% for Lidar-Only. QC-A* shifts sensor degradation modeling from empirical penalty to physical mechanism, achieving a favorable safety–efficiency balance prioritizing perceptual safety, and provides an interpretable, generalizable framework for robotic fire-environment path planning.

SensorsVol. 26(14)
Hangzhou Normal University (CN), China Mobile (China) (CN), National Medical Products Administration (CN), Zhejiang Zanyu Technology (China) (CN), Zhejiang Academy of Medical Sciences (CN)
Openalex Percentile: Top 9%
Fire Detection and Safety Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.