Cardiovascular 4D Flow MRI for multidirectional hemodynamic assessment: a single-centre observational study

OBJECTIVES: To evaluate the feasibility and clinical utility of cardiovascular four-dimensional flow magnetic resonance imaging (4D Flow MRI) for multidirectional hemodynamic visualization and quantitative assessment. METHODS: This single-centre observational study included 30 cardiovascular MRI cases acquired at Huaqiao University Affiliated Strait Hospital using a Siemens MAGNETOM Skyra 3.0-T system with an 18-channel phased-array coil. Time-resolved three-dimensional velocity-encoded 4D Flow MRI was performed with retrospective electrocardiographic gating, respiratory compensation, and region-adjusted velocity encoding. Acquisition parameters included TR/TE 38.88/6.88 ms, flip angle 8°, matrix 256 × 256, field of view 300 mm, in-plane spatial resolution 1.4 × 1.4 mm, slice thickness 3 mm, and slice gap 0.6 mm. Preprocessing corrected background phase offsets, Maxwell terms, velocity aliasing, and noise artefacts. RESULTS: 4D Flow MRI enabled assessment of intracardiac shunting, pulmonary regurgitation, Fontan circulation, bicuspid aortic valve hemodynamics, aortic regurgitation, and atrioventricular valve dysfunction. Quantified parameters included pulmonary-to-systemic flow ratio, shunt volume, regurgitant fraction, peak velocity, pressure gradient, wall shear stress, vorticity, helicity, kinetic energy, turbulent kinetic energy, oscillatory shear index, and energy loss. CONCLUSIONS: Cardiovascular 4D Flow MRI supports patient-specific hemodynamic assessment across complex cardiovascular conditions within a practical single-centre clinical workflow with retrospective quantification.

Authors

Institutions

Publication Details

Journal
Biomedizinische Technik/Biomedical Engineering
Published
2026-07-17
DOI
https://doi.org/10.1515/bmt-2026-0281
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cardiovascular 4D Flow MRI for multidirectional hemodynamic assessment: a single-centre observational study

Taisheng Zeng, J-M Huang, Yusi Chen, Zhihua Liu et al.
Biomedizinische Technik/Biomedical Engineering
Advanced MRI Techniques and Applications
article

Cardiovascular 4D Flow MRI for multidirectional hemodynamic assessment: a single-centre observational study

Taisheng Zeng, J-M Huang, Yusi Chen, Zhihua Liu, Yi-Jen Huang, Bijiao Ding, Jianshe Shi, Yuguang Ye
article en

Abstract

OBJECTIVES: To evaluate the feasibility and clinical utility of cardiovascular four-dimensional flow magnetic resonance imaging (4D Flow MRI) for multidirectional hemodynamic visualization and quantitative assessment. METHODS: This single-centre observational study included 30 cardiovascular MRI cases acquired at Huaqiao University Affiliated Strait Hospital using a Siemens MAGNETOM Skyra 3.0-T system with an 18-channel phased-array coil. Time-resolved three-dimensional velocity-encoded 4D Flow MRI was performed with retrospective electrocardiographic gating, respiratory compensation, and region-adjusted velocity encoding. Acquisition parameters included TR/TE 38.88/6.88 ms, flip angle 8°, matrix 256 × 256, field of view 300 mm, in-plane spatial resolution 1.4 × 1.4 mm, slice thickness 3 mm, and slice gap 0.6 mm. Preprocessing corrected background phase offsets, Maxwell terms, velocity aliasing, and noise artefacts. RESULTS: 4D Flow MRI enabled assessment of intracardiac shunting, pulmonary regurgitation, Fontan circulation, bicuspid aortic valve hemodynamics, aortic regurgitation, and atrioventricular valve dysfunction. Quantified parameters included pulmonary-to-systemic flow ratio, shunt volume, regurgitant fraction, peak velocity, pressure gradient, wall shear stress, vorticity, helicity, kinetic energy, turbulent kinetic energy, oscillatory shear index, and energy loss. CONCLUSIONS: Cardiovascular 4D Flow MRI supports patient-specific hemodynamic assessment across complex cardiovascular conditions within a practical single-centre clinical workflow with retrospective quantification.

Biomedizinische Technik/Biomedical Engineering
Huaqiao University (CN), Fujian Medical University (CN), Quanzhou Normal University (CN), Quzhou University (CN)
Good health and well-being
Openalex Percentile: Top 8%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.