RESULTS OF SUPRAPECTINEAL PLATING FOR DISPLACED QUADRANGULAR PLATE ACETABULAR FRACTURES

Complex acetabular fractures involving the quadrilateral plate are challenging to treat. Rigid, stable, anatomic fixation using implants like the supra-pectineal plate has shown promising results even with poor bone quality and severe comminution. However, there is no consensus on the optimal implant choice for these fractures. Our study across 2 Major Trauma Centres (MTC's) in the Greater Manchester region between 2020–2025 retrospectively reviewed 30 patients treated with supra-pectineal plating for displaced quadrilateral plate fractures using the modified Stoppa approach. Peri and post-operative results (minimum follow-up of 12 months) were evaluated for quality of reduction, time to union, functional recovery, peri-operative complications and development of post-traumatic arthritis. Objective evaluation was done using Oxford Hip Score (OHS). Out of the 30 patients, 60%(n=18) were male and the group had a median age of 55 years (range 22–88 years). Median length of hospital stay was 17.5 days. While 93% (n=28) patients had satisfactory to good post -op reduction (CT/X-Ray), reduction quality was deemed poor in 7% (n=2) patients. Average time to confirmed radiological union was 6.25 months. OHS was calculated for 29 patients of which 17% (n=5) reported severe symptoms (OHS 0 to 19), 4% (n=1) reported moderate to severe symptoms (OHS 20 to 29), 43% (n=13) had mild to moderate symptoms (OHS 30 to 39), and 35% (n=10) reported satisfactory joint function (OHS 40 to 48). Failure of metalwork was reported in one patient. Thus, in our cohort of patients, supra-pectineal plating provided satisfactory hip function post-op for majority of the patients with an OHS >30 and good reduction was achieved in 93% of our cohort as confirmed by post-op imaging.

Authors

Institutions

Publication Details

Journal
Orthopaedic Proceedings
Published
2026-07-17
DOI
https://doi.org/10.1302/1358-992x.2026.5.004
Primary Topic
Pelvic and Acetabular Injuries
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RESULTS OF SUPRAPECTINEAL PLATING FOR DISPLACED QUADRANGULAR PLATE ACETABULAR FRACTURES

J. Taylor, N. Shah, M. R. Iqbal, E. Ahmed et al.
Orthopaedic Proceedings
Pelvic and Acetabular Injuries
article

RESULTS OF SUPRAPECTINEAL PLATING FOR DISPLACED QUADRANGULAR PLATE ACETABULAR FRACTURES

J. Taylor, N. Shah, M. R. Iqbal, E. Ahmed, S. Patwardhan, I. Gill, V. H. Kempanna
article en

Abstract

Complex acetabular fractures involving the quadrilateral plate are challenging to treat. Rigid, stable, anatomic fixation using implants like the supra-pectineal plate has shown promising results even with poor bone quality and severe comminution. However, there is no consensus on the optimal implant choice for these fractures. Our study across 2 Major Trauma Centres (MTC's) in the Greater Manchester region between 2020–2025 retrospectively reviewed 30 patients treated with supra-pectineal plating for displaced quadrilateral plate fractures using the modified Stoppa approach. Peri and post-operative results (minimum follow-up of 12 months) were evaluated for quality of reduction, time to union, functional recovery, peri-operative complications and development of post-traumatic arthritis. Objective evaluation was done using Oxford Hip Score (OHS). Out of the 30 patients, 60%(n=18) were male and the group had a median age of 55 years (range 22–88 years). Median length of hospital stay was 17.5 days. While 93% (n=28) patients had satisfactory to good post -op reduction (CT/X-Ray), reduction quality was deemed poor in 7% (n=2) patients. Average time to confirmed radiological union was 6.25 months. OHS was calculated for 29 patients of which 17% (n=5) reported severe symptoms (OHS 0 to 19), 4% (n=1) reported moderate to severe symptoms (OHS 20 to 29), 43% (n=13) had mild to moderate symptoms (OHS 30 to 39), and 35% (n=10) reported satisfactory joint function (OHS 40 to 48). Failure of metalwork was reported in one patient. Thus, in our cohort of patients, supra-pectineal plating provided satisfactory hip function post-op for majority of the patients with an OHS >30 and good reduction was achieved in 93% of our cohort as confirmed by post-op imaging.

Orthopaedic ProceedingsVol. 108-B(SUPP_5)
Glan Clwyd Hospital (GB), Manchester Royal Infirmary (GB), Wrightington Hospital (GB), Salford Royal Hospital (GB)
No poverty
Openalex Percentile: Top 7%
Pelvic and Acetabular Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

RESULTS OF SUPRAPECTINEAL PLATING FOR DISPLACED QUADRANGULAR PLATE ACETABULAR FRACTURES — J. Taylor, N. Shah, et al. · Orthopaedic Proceedings (2026) | TGRS Research Map | TGRS