Comparison of endothelin-1 levels in plasma from human coronary arteries measured by enzyme linked immunosorbent assay and Olink high-throughput proteomics platform

Endothelin 1 (ET 1) antagonists are increasingly being approved for new treatments for cardiovascular disease, where elevated ET-1 levels contribute to increased vasoconstriction. Further therapeutic targets, including coronary artery disease, are under investigation. The Olink Explore 3072 Proximity Extension Assay platform enables multiplexed high throughput measurement of ~3000 plasma proteins, from minimal (≤6µl) sample volumes. However, it is not known if the two oligonucleotide‑tagged antibodies raised against preproET-1₁-₂₁₂, used in this Olink assay, specifically measure biologically active ET 1 or the other inactive EDN1 encoded peptides, also secreted by human endothelial cells. Paired plasma samples from 29 patients with coronary artery disease were obtained, using a specialised intra-coronary sampling catheter, designed to obtain site specific biochemical information from within coronary arteries. We compared ET 1 concentrations measured with an ET-1 specific ELISA, demonstrated to have no cross reactivity with other EDN1 encoded peptides versus values obtained using Olink Explore platform. Olink measured ET 1 correlated significantly with ELISA derived ET 1 levels (r=0.53, p=0.003), and Olink values predicted ELISA results. Olink ET 1 concentrations also correlated with ETB receptor levels (r=0.40, p< 0.05). These findings indicate that the Olink Explore platform can detect relative changes in biologically active ET 1, supporting its use as a biomarker tool in clinical and translational studies.

Authors

Publication Details

Journal
Apollo
Published
2026-07-17
DOI
https://doi.org/10.17863/cam.132262
Primary Topic
Nitric Oxide and Endothelin Effects
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of endothelin-1 levels in plasma from human coronary arteries measured by enzyme linked immunosorbent assay and Olink high-throughput proteomics platform

Diane Proudfoot, Anthony P. Davenport, Janet Maguire, Stephen Hoole et al.
Apollo
Nitric Oxide and Endothelin Effects
article

Comparison of endothelin-1 levels in plasma from human coronary arteries measured by enzyme linked immunosorbent assay and Olink high-throughput proteomics platform

Diane Proudfoot, Anthony P. Davenport, Janet Maguire, Stephen Hoole, Majid Anwar, Rhoda Kuc, George Abraham, Catherine Bullock
article en

Abstract

Endothelin 1 (ET 1) antagonists are increasingly being approved for new treatments for cardiovascular disease, where elevated ET-1 levels contribute to increased vasoconstriction. Further therapeutic targets, including coronary artery disease, are under investigation. The Olink Explore 3072 Proximity Extension Assay platform enables multiplexed high throughput measurement of ~3000 plasma proteins, from minimal (≤6µl) sample volumes. However, it is not known if the two oligonucleotide‑tagged antibodies raised against preproET-1₁-₂₁₂, used in this Olink assay, specifically measure biologically active ET 1 or the other inactive EDN1 encoded peptides, also secreted by human endothelial cells. Paired plasma samples from 29 patients with coronary artery disease were obtained, using a specialised intra-coronary sampling catheter, designed to obtain site specific biochemical information from within coronary arteries. We compared ET 1 concentrations measured with an ET-1 specific ELISA, demonstrated to have no cross reactivity with other EDN1 encoded peptides versus values obtained using Olink Explore platform. Olink measured ET 1 correlated significantly with ELISA derived ET 1 levels (r=0.53, p=0.003), and Olink values predicted ELISA results. Olink ET 1 concentrations also correlated with ETB receptor levels (r=0.40, p< 0.05). These findings indicate that the Olink Explore platform can detect relative changes in biologically active ET 1, supporting its use as a biomarker tool in clinical and translational studies.

Apollo
Wellcome Trust
Good health and well-being
Openalex Percentile: Top 9%
Nitric Oxide and Endothelin Effects
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of endothelin-1 levels in plasma from human coronary arteries measured by enzyme linked immunosorbent assay and Olink high-throughput proteomics platform — Diane Proudfoot, Anthony P. Davenport, et al. · Apollo (2026) | TGRS Research Map | TGRS