Does Measurement Site Matter? A Comparison Between Finger, Forehead, and Toe Pulse Oximetry Measurements in Polysomnography

ABSTRACT Accurate peripheral blood oxygen saturation (SpO 2 ) measurements are critical for evaluating sleep patients, particularly those with frequent desaturations due to pathological breathing events. We compared synchronised SpO 2 measurements obtained from three anatomical sites (finger, forehead and toe) in patients undergoing routine Type 1 polysomnography (PSG) to assess site‐related variability. Continuous and simultaneous pulse oximetry recordings from 41 sleep patients were synchronised with PSG data and scored for SpO 2 desaturations (≥ 3% and ≥ 10 s), signal dropouts and artefact occurrences. Forehead and toe SpO 2 measurements were compared against finger oximetry, the standard PSG oximetry site. Significant differences were observed between anatomical sites for mean SpO 2 ( p < 0.01), mean SpO 2 desaturations per hour ( p < 0.01) and time spent below an SpO 2 level of 95% during total sleep time ( p < 0.01). Forehead pulse oximetry demonstrated the highest mean SpO 2 , the fewest SpO 2 desaturations per hour and the least artefact occurrences ( p = 0.024), while finger oximetry exhibited the most signal dropouts ( p < 0.01). Finger and toe pulse oximetry showed the strongest concordance for SpO 2 desaturations per hour ( r = 0.948). Observed differences in SpO 2 measurements are likely due to perfusion variability between peripheral and core circulation during sudden blood pressure oscillations associated with sleep disordered breathing. Our findings highlight that anatomical site choice for measuring SpO 2 during PSG may have significant implications in the severity classification, diagnosis and treatment of sleep disorders; especially for limited channel sleep studies that rely primarily on oximetry. Further research is required to determine which anatomical site reflects true arterial oxygenation in sleep patients.

Authors

Institutions

Publication Details

Journal
Journal of Sleep Research
Published
2026-07-16
DOI
https://doi.org/10.1111/jsr.70400
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Does Measurement Site Matter? A Comparison Between Finger, Forehead, and Toe Pulse Oximetry Measurements in Polysomnography

Leigh Wilks, Kellie R. Strickland, Peter K. Dunn, Chris J. Brown et al.
Journal of Sleep Research
Non-Invasive Vital Sign Monitoring
article

Does Measurement Site Matter? A Comparison Between Finger, Forehead, and Toe Pulse Oximetry Measurements in Polysomnography

Leigh Wilks, Kellie R. Strickland, Peter K. Dunn, Chris J. Brown, Mark A. Holmes
article en

Abstract

ABSTRACT Accurate peripheral blood oxygen saturation (SpO 2 ) measurements are critical for evaluating sleep patients, particularly those with frequent desaturations due to pathological breathing events. We compared synchronised SpO 2 measurements obtained from three anatomical sites (finger, forehead and toe) in patients undergoing routine Type 1 polysomnography (PSG) to assess site‐related variability. Continuous and simultaneous pulse oximetry recordings from 41 sleep patients were synchronised with PSG data and scored for SpO 2 desaturations (≥ 3% and ≥ 10 s), signal dropouts and artefact occurrences. Forehead and toe SpO 2 measurements were compared against finger oximetry, the standard PSG oximetry site. Significant differences were observed between anatomical sites for mean SpO 2 ( p < 0.01), mean SpO 2 desaturations per hour ( p < 0.01) and time spent below an SpO 2 level of 95% during total sleep time ( p < 0.01). Forehead pulse oximetry demonstrated the highest mean SpO 2 , the fewest SpO 2 desaturations per hour and the least artefact occurrences ( p = 0.024), while finger oximetry exhibited the most signal dropouts ( p < 0.01). Finger and toe pulse oximetry showed the strongest concordance for SpO 2 desaturations per hour ( r = 0.948). Observed differences in SpO 2 measurements are likely due to perfusion variability between peripheral and core circulation during sudden blood pressure oscillations associated with sleep disordered breathing. Our findings highlight that anatomical site choice for measuring SpO 2 during PSG may have significant implications in the severity classification, diagnosis and treatment of sleep disorders; especially for limited channel sleep studies that rely primarily on oximetry. Further research is required to determine which anatomical site reflects true arterial oxygenation in sleep patients.

Journal of Sleep Research
University of the Sunshine Coast (AU), Sunshine Coast University Hospital (AU)
Openalex Percentile: Top 15%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.