A randomized controlled trial of remote monitoring for cardiac implantable loop recorders: stay-away trial
BACKGROUND AND AIMS: The benefits of remote monitoring (RM) for pacemakers and defibrillators have been established. It has not been shown that these benefits apply to implantable loop recorders (ILRs). We aimed to investigate the effect of RM on patient outcomes, time spent, and cost during follow-up of ILRs. METHODS: We conducted a multi-centre, randomized, controlled, open-label trial of RM versus office-based follow-up for ILRs. At implant, patients were randomized to RM only, or office visits at 6 weeks, 6 months, and 12 months (no-RM). Primary efficacy endpoints were: (1) time from event to diagnosis, (2) number of related hospital presentations. Secondary endpoints were time spent on follow-up, satisfaction, and cost. RESULTS: One hundred consecutively referred patients, aged 61 ± 18yrs, 53% male, were recruited between April 2018 and September 2019 (pre-COVID pandemic). Follow-up was 12 months. Patients with RM versus no-RM had less time from event to diagnosis (RM 0(0-0) days, no-RM 40(33-42) days, P < 0.001), fewer arrhythmia-related hospital presentations (RM 0.7 ± 1.1, no-RM 2.8 ± 2.6, P < 0.019), and lower (better) satisfaction survey scores (RM 13 ± 4, no-RM 16 ± 5; P = 0.041). Follow-up clinician time spent (RM 33 ± 29 min, no-RM 29 ± 26 min, P = 0.063) and cost of follow up (RM $803, no-RM $1,090; P = 0.347) were not different. CONCLUSIONS: In patients with ILRs randomized to receive RM, there was less time from event to diagnosis, there were fewer hospital and clinic presentations, and improved patient satisfaction. RM did not take more time and was cost effective in the Australian health care system. This study provides support for RM of ILRs. REGISTRATION: ACTRN12618001359224.
Authors
- Andrew Boyle (ORCID: https://orcid.org/0000-0002-3919-5269)
- S. Sugito
- Austin N May
- Nicholas Jackson (ORCID: https://orcid.org/0000-0001-9691-9561)
- J. Leitch
- Amardeep Amardeep
- John L. Fitzgerald
- Bradley Wilsmore
- Aaron L. Sverdlov
- Gwilym M. Morris
- Stuart Turner
- David Baker
- Malcolm Barlow
- Nicholas Collins
Institutions
- John Hunter Hospital (AU)
- Hunter Medical Research Institute (AU)
- The University of Adelaide (AU)
- University of Newcastle Australia (AU)
Publication Details
- Journal
- Journal of Interventional Cardiac Electrophysiology
- Published
- 2026-07-17
- DOI
- https://doi.org/10.1007/s10840-026-02375-x
- Primary Topic
- Cardiac pacing and defibrillation studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Newcastle University