Optimally controlled nuclear magnetic resonance (NMR) in electrochemistry: Larmor versus nutation frequency selective spin excitation for locally selective NMR experiments

Abstract. Spectroelectrochemical nuclear magnetic resonance (NMR) experiments are faced with numerous challenges originating from shielding effects and susceptibility gradients in samples, leading to inhomogeneities in the static magnetic fields B0 and the radio frequency (rf) fields B1. Moreover, magnetic feedback caused by eddy currents in conductors can obstruct precise measurements. Previous works have shown that these eddy-current-induced magnetic field distortions can be accurately predicted by finite element method (FEM) simulations. In this work, we present a workflow combining FEM predictions with quantum optimal control (QOC) to tailor custom NMR pulses that exploit specific magnetic field distortions for selective excitation of affected sample regions. The desired selectivity was achieved using pattern pulses optimized for either a particular B1 or Larmor frequency ν0. Experimental validation was performed on a heterogeneous phantom consisting of two cavities filled with two spectroscopically distinguishable liquids, one between copper disks to mimic an electrochemical cell and one between polymer disks as a reference. An over 30-fold suppression of the reference resonance in between polymer compared to the resonance in between copper disks was achieved, demonstrating how QOC-tailored pulses can selectively address FEM-predicted B1 distortions in the vicinity of electrical conductors to achieve spatial selectivity with simultaneous ν0 robustness. It was also demonstrated how QOC-tailored pulses can selectively excite specific ν0 despite B0 distortions, which implies that difficulties with conventional solvent suppression techniques in electrochemical setups can be mitigated using the adjustable robustness of QOC-tailored pulses. The presented approach sets the stage for gradient-free, localized in operando NMR in electrochemistry and material sciences, with the prospect of surface selectivity down to the detection limit of the setup.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance
Published
2026-07-17
DOI
https://doi.org/10.5194/mr-7-113-2026
Primary Topic
NMR spectroscopy and applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimally controlled nuclear magnetic resonance (NMR) in electrochemistry: Larmor versus nutation frequency selective spin excitation for locally selective NMR experiments

Michael Schatz, Sven Jovanovic, S. Kocher, M. Streun et al.
Magnetic Resonance
NMR spectroscopy and applications
article

Optimally controlled nuclear magnetic resonance (NMR) in electrochemistry: Larmor versus nutation frequency selective spin excitation for locally selective NMR experiments

Michael Schatz, Sven Jovanovic, S. Kocher, M. Streun, Armin J. Römer, Rüdiger‐A. Eichel, Johannes F. Kochs, Josef Granwehr
article en

Abstract

Abstract. Spectroelectrochemical nuclear magnetic resonance (NMR) experiments are faced with numerous challenges originating from shielding effects and susceptibility gradients in samples, leading to inhomogeneities in the static magnetic fields B0 and the radio frequency (rf) fields B1. Moreover, magnetic feedback caused by eddy currents in conductors can obstruct precise measurements. Previous works have shown that these eddy-current-induced magnetic field distortions can be accurately predicted by finite element method (FEM) simulations. In this work, we present a workflow combining FEM predictions with quantum optimal control (QOC) to tailor custom NMR pulses that exploit specific magnetic field distortions for selective excitation of affected sample regions. The desired selectivity was achieved using pattern pulses optimized for either a particular B1 or Larmor frequency ν0. Experimental validation was performed on a heterogeneous phantom consisting of two cavities filled with two spectroscopically distinguishable liquids, one between copper disks to mimic an electrochemical cell and one between polymer disks as a reference. An over 30-fold suppression of the reference resonance in between polymer compared to the resonance in between copper disks was achieved, demonstrating how QOC-tailored pulses can selectively address FEM-predicted B1 distortions in the vicinity of electrical conductors to achieve spatial selectivity with simultaneous ν0 robustness. It was also demonstrated how QOC-tailored pulses can selectively excite specific ν0 despite B0 distortions, which implies that difficulties with conventional solvent suppression techniques in electrochemical setups can be mitigated using the adjustable robustness of QOC-tailored pulses. The presented approach sets the stage for gradient-free, localized in operando NMR in electrochemistry and material sciences, with the prospect of surface selectivity down to the detection limit of the setup.

Magnetic ResonanceVol. 7(2)
Forschungszentrum Jülich (DE), Fritz Haber Institute of the Max Planck Society (DE), RWTH Aachen University (DE)
Deutsche Forschungsgemeinschaft, Bundesministerium für Forschung und Technologie
Openalex Percentile: Top 10%
NMR spectroscopy and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.