Measuring cardiac stroke volume through in-ear audio sensing

Stroke volume, the volume of blood ejected by the left ventricle during a contraction, is a key metric of cardiovascular health. Currently, stroke volume is measured in clinic with specialised equipment. While purpose-made wearables exist to measure stroke volume, no solution relies solely on commodity devices. We present a deep learning system for stroke volume estimation from in-ear audio of earbuds. We combine generative self-supervised/transfer learning, a transformer-based autoencoder, to predict average stroke volume in unseen subjects. With data from 23 healthy participants, we compare our estimations to clinically validated device estimations. We achieve a mean absolute error of 5.24 ml, a Pearson correlation of r=0.94 between average predicted stroke volume and average true stroke volume, and a Percentage Error in the limits of agreement of 11.05% (within clinical range for stroke volume measurement devices). These findings open the doors to longitudinal, scalable and affordable cardiovascular measurement out of clinic.

Authors

Institutions

Publication Details

Journal
Nature Communications
Published
2026-07-17
DOI
https://doi.org/10.1038/s41467-026-75642-0
Primary Topic
Phonocardiography and Auscultation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measuring cardiac stroke volume through in-ear audio sensing

Navazh Jalaludeen, Cecilia Mascolo, Qiang Yang, Yang Liu et al.
Nature Communications
Phonocardiography and Auscultation Techniques
article

Measuring cardiac stroke volume through in-ear audio sensing

Navazh Jalaludeen, Cecilia Mascolo, Qiang Yang, Yang Liu, Kayla-Jade Butkow, Joseph Cheriyan, Jake Stuchbury-Wass, Mathias Ciliberto, Dong Ma
article en

Abstract

Stroke volume, the volume of blood ejected by the left ventricle during a contraction, is a key metric of cardiovascular health. Currently, stroke volume is measured in clinic with specialised equipment. While purpose-made wearables exist to measure stroke volume, no solution relies solely on commodity devices. We present a deep learning system for stroke volume estimation from in-ear audio of earbuds. We combine generative self-supervised/transfer learning, a transformer-based autoencoder, to predict average stroke volume in unseen subjects. With data from 23 healthy participants, we compare our estimations to clinically validated device estimations. We achieve a mean absolute error of 5.24 ml, a Pearson correlation of r=0.94 between average predicted stroke volume and average true stroke volume, and a Percentage Error in the limits of agreement of 11.05% (within clinical range for stroke volume measurement devices). These findings open the doors to longitudinal, scalable and affordable cardiovascular measurement out of clinic.

Nature Communications
University of Cambridge (GB), Cambridge University Hospitals NHS Foundation Trust (GB), OSE Immunotherapeutics (France) (FR), Oncotherapeutics (United States) (US)
National Institute for Health and Care Research, Department of Health and Social Care, Engineering and Physical Sciences Research Council, NIHR Cambridge Biomedical Research Centre
Openalex Percentile: Top 9%
Phonocardiography and Auscultation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.