Physiology-Based Identifiable Model-Quantity Subset Selection for Early Prediction of Intradialytic MAP Trajectories from Sparse Observations

Intradialytic hypotension (IDH) is a common and harmful complication of hemodialysis that is closely associated with changes in mean arterial pressure (MAP). However, mechanistic prediction of intradialytic MAP is hindered by sparse early-stage observations and model-quantity non identifiability in physiology-based models. This study develops a dimensionality-reduced predictive framework following a screen-select-estimate workflow for early prediction of intradialytic MAP trajectories from sparse MAP observations. Among 35 candidate model quantities considered in the screening procedure, the initial blood volume Vb0 and post-capillary venous resistance Rs3 are selected for estimation, whereas the remaining candidate quantities and treatment inputs are kept fixed or prescribed. Sensitivity analysis and Fisher information matrix (FIM)-based subset selection show that this two-quantity subset provides the best trade-off between physiological information content, identifiability, and numerical stability. Using MAP observations from the first 100 min of dialysis, the selected subset supports prediction of subsequent MAP trajectories across four representative patient types. At the end of the 240-min ultrafiltration period, corresponding to approximately 3.00 L prescribed ultrafiltration in the reference simulation, the model-derived terminal specific blood volume ranges from 66.48 to 69.19 mL/kg and RBV(240) ranges from 88.74% to 91.83% across the four phenotypes. Prediction-phase root-mean-square error (RMSE) ranges from 1.09 to 5.78 mmHg, and the maximum error ranges from 1.71 to 8.51 mmHg. This patient-type-level framework enables interpretable MAP trajectory prediction and provides a methodological basis for future patient-level evaluation of IDH-related MAP decline.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2026-07-17
DOI
https://doi.org/10.1088/1873-4030/ae8c1c
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physiology-Based Identifiable Model-Quantity Subset Selection for Early Prediction of Intradialytic MAP Trajectories from Sparse Observations

P Q Li, Haitao Zhang, Xiaobo Rao, Jun Zhang et al.
Medical Engineering & Physics
Hemodynamic Monitoring and Therapy
article

Physiology-Based Identifiable Model-Quantity Subset Selection for Early Prediction of Intradialytic MAP Trajectories from Sparse Observations

P Q Li, Haitao Zhang, Xiaobo Rao, Jun Zhang, Fengmin Shao
article en

Abstract

Intradialytic hypotension (IDH) is a common and harmful complication of hemodialysis that is closely associated with changes in mean arterial pressure (MAP). However, mechanistic prediction of intradialytic MAP is hindered by sparse early-stage observations and model-quantity non identifiability in physiology-based models. This study develops a dimensionality-reduced predictive framework following a screen-select-estimate workflow for early prediction of intradialytic MAP trajectories from sparse MAP observations. Among 35 candidate model quantities considered in the screening procedure, the initial blood volume Vb0 and post-capillary venous resistance Rs3 are selected for estimation, whereas the remaining candidate quantities and treatment inputs are kept fixed or prescribed. Sensitivity analysis and Fisher information matrix (FIM)-based subset selection show that this two-quantity subset provides the best trade-off between physiological information content, identifiability, and numerical stability. Using MAP observations from the first 100 min of dialysis, the selected subset supports prediction of subsequent MAP trajectories across four representative patient types. At the end of the 240-min ultrafiltration period, corresponding to approximately 3.00 L prescribed ultrafiltration in the reference simulation, the model-derived terminal specific blood volume ranges from 66.48 to 69.19 mL/kg and RBV(240) ranges from 88.74% to 91.83% across the four phenotypes. Prediction-phase root-mean-square error (RMSE) ranges from 1.09 to 5.78 mmHg, and the maximum error ranges from 1.71 to 8.51 mmHg. This patient-type-level framework enables interpretable MAP trajectory prediction and provides a methodological basis for future patient-level evaluation of IDH-related MAP decline.

Medical Engineering & Physics
Zhengzhou University (CN), Zhengzhou People's Hospital (CN)
Henan Provincial Science and Technology Research Project
Openalex Percentile: Top 7%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.