Measurement Reactivity to Hip-Worn Accelerometry Among Adolescent Females: A Concurrent Wear Approach

Device-based measurement of physical activity (PA) is crucial for valid research, but reactivity to these devices can undermine validity. Inconsistent findings in prior reactivity research warrant unique approaches among diverse populations, including those habituated to wearing another device. We aimed to estimate reactivity to ActiGraph GT3X+ via concurrent Fitbit Inspire HR wear among Latina adolescents using a person-day matched cross-sectional design. Fitbit data estimated steps, moderate-vigorous PA, light PA, and sedentary time for all days in the 2 weeks preceding and following matched ActiGraph wear days. Linear models estimated the association of ActiGraph wear day with activity after adjustment for covariates. There were 2987 total days across 107 participants, ~35% classified as ActiGraph wear days. Steps statistically significantly differed (p = .0499) with ActiGraph wear days corresponding to 248 greater average steps. Measurement reactivity to ActiGraph may impact steps among adolescent females. Future research could benefit from concurrent wear strategies if feasible.

Authors

Institutions

Publication Details

Journal
Measurement in Physical Education and Exercise Science
Published
2026-07-16
DOI
https://doi.org/10.1080/1091367x.2026.2704743
Primary Topic
Physical Activity and Health
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement Reactivity to Hip-Worn Accelerometry Among Adolescent Females: A Concurrent Wear Approach

Esmeralda Castro, Michael Higgins, Jacob Carson, Job Godino et al.
Measurement in Physical Education and Exercise Science
Physical Activity and Health
article

Measurement Reactivity to Hip-Worn Accelerometry Among Adolescent Females: A Concurrent Wear Approach

Esmeralda Castro, Michael Higgins, Jacob Carson, Job Godino, Britta Larsen
article en

Abstract

Device-based measurement of physical activity (PA) is crucial for valid research, but reactivity to these devices can undermine validity. Inconsistent findings in prior reactivity research warrant unique approaches among diverse populations, including those habituated to wearing another device. We aimed to estimate reactivity to ActiGraph GT3X+ via concurrent Fitbit Inspire HR wear among Latina adolescents using a person-day matched cross-sectional design. Fitbit data estimated steps, moderate-vigorous PA, light PA, and sedentary time for all days in the 2 weeks preceding and following matched ActiGraph wear days. Linear models estimated the association of ActiGraph wear day with activity after adjustment for covariates. There were 2987 total days across 107 participants, ~35% classified as ActiGraph wear days. Steps statistically significantly differed (p = .0499) with ActiGraph wear days corresponding to 248 greater average steps. Measurement reactivity to ActiGraph may impact steps among adolescent females. Future research could benefit from concurrent wear strategies if feasible.

Measurement in Physical Education and Exercise Science
University of California San Diego (US), Family Health Centers of San Diego (US)
Gender equality
Openalex Percentile: Top 9%
Physical Activity and Health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.