Experimental Research and Simulation for the Performance of an R290 Heat Pump with Independent Compression

Since the Kigali Amendment entered into force globally, propane (R290) has been regarded as one of the most promising next-generation alternative refrigerants for refrigeration and air conditioning. However, its flammability limits its maximum charge amount and leads to higher flow resistance loss. In this paper, a novel refrigeration cycle with an additional independent compression process was simulated and experimentally tested. The simulation error of capacity was less than 7.1%. The intermediate evaporation temperature was optimized. The results show that the new cycle delivers stable performance advantages over the conventional R290 heat pump in both cooling and heating modes, with average capacity and COP improvements of 4.8% and 7.8% for cooling, and 8.3% and 7.5% for heating. System flow resistance loss decreases by 33.0%, which raises the refrigerant mass flow rate by 12.5% and reduces the required compressor displacement by 6.6% at equivalent cooling capacity on average.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-07-16
DOI
https://doi.org/10.3390/en19143367
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Research and Simulation for the Performance of an R290 Heat Pump with Independent Compression

Tingxun Li, Jiangqi He
Energies
Refrigeration and Air Conditioning Technologies
article

Experimental Research and Simulation for the Performance of an R290 Heat Pump with Independent Compression

Tingxun Li, Jiangqi He
article en

Abstract

Since the Kigali Amendment entered into force globally, propane (R290) has been regarded as one of the most promising next-generation alternative refrigerants for refrigeration and air conditioning. However, its flammability limits its maximum charge amount and leads to higher flow resistance loss. In this paper, a novel refrigeration cycle with an additional independent compression process was simulated and experimentally tested. The simulation error of capacity was less than 7.1%. The intermediate evaporation temperature was optimized. The results show that the new cycle delivers stable performance advantages over the conventional R290 heat pump in both cooling and heating modes, with average capacity and COP improvements of 4.8% and 7.8% for cooling, and 8.3% and 7.5% for heating. System flow resistance loss decreases by 33.0%, which raises the refrigerant mass flow rate by 12.5% and reduces the required compressor displacement by 6.6% at equivalent cooling capacity on average.

EnergiesVol. 19(14)
Sun Yat-sen University (CN)
National Natural Science Foundation of China, Ministry of Environmental Protection
Affordable and clean energy
Openalex Percentile: Top 15%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.