Initial Cytotoxicity of Additively and Subtractively Manufactured Resin‐Based Materials for Interim Fixed Dental Prostheses: An In Vitro Study

OBJECTIVES: To compare the initial cytotoxic response of additively manufactured (AM) and subtractively manufactured (SM) resin-based materials for interim fixed dental prostheses (FDPs) under indirect and direct in vitro exposure conditions. MATERIAL AND METHODS: A total of 216 standardized resin discs were fabricated from AM resins (Group P, n = 108) and SM polymethyl methacrylate (PMMA)-based resins (Group M, n = 108). L929 mouse fibroblasts were used as the biological model, with a negative control group (Group C, n = 36). After 24 h of cell attachment, cell viability was assessed after 72 h under two conditions: indirect exposure to resin eluates and direct contact with resin discs. Viability was quantified by crystal violet staining. Data were analyzed using Kruskal-Wallis tests followed by Dunn's pairwise post hoc comparisons (α = 0.05). RESULTS: In the indirect assay, Group M showed 87% cell survival relative to the control, whereas Group P showed 65%; in the direct assay, values were 89% and 48%, respectively. Significant differences were observed among pooled groups in both assays (p < 0.001). Based on ISO 10993-5 thresholds, Group P was classified as slightly cytotoxic in the indirect assay and moderately cytotoxic in the direct assay, whereas Group M remained within the non-cytotoxic to slightly cytotoxic range. Group P showed significantly lower cell viability than Group M in both assays (adjusted p < 0.001), while no statistically significant differences were detected within each manufacturing category (adjusted p > 0.05). CONCLUSIONS: At 72 h, the tested AM resins showed significantly lower cell viability than the tested SM PMMA-based resins under the present in vitro conditions. CLINICAL SIGNIFICANCE: The lower cell viability observed for the tested 3D-printed interim materials under short-term in vitro conditions highlights the need for caution when extrapolating 72-h cell-viability findings to clinical performance and supports further standardized long-term in vitro and in vivo investigations.

Authors

Institutions

Publication Details

Journal
Clinical and Experimental Dental Research
Published
2026-07-16
DOI
https://doi.org/10.1002/cre2.70413
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Initial Cytotoxicity of Additively and Subtractively Manufactured Resin‐Based Materials for Interim Fixed Dental Prostheses: An In Vitro Study

Blanca Herrera, Aranzazu Sánchez, José M. Alegre, Seyed Ali Mosaddad et al.
Clinical and Experimental Dental Research
Dental materials and restorations
article

Initial Cytotoxicity of Additively and Subtractively Manufactured Resin‐Based Materials for Interim Fixed Dental Prostheses: An In Vitro Study

Blanca Herrera, Aranzazu Sánchez, José M. Alegre, Seyed Ali Mosaddad, María J. Suárez, Pedro Diaz, Jesús Peláez
article en

Abstract

OBJECTIVES: To compare the initial cytotoxic response of additively manufactured (AM) and subtractively manufactured (SM) resin-based materials for interim fixed dental prostheses (FDPs) under indirect and direct in vitro exposure conditions. MATERIAL AND METHODS: A total of 216 standardized resin discs were fabricated from AM resins (Group P, n = 108) and SM polymethyl methacrylate (PMMA)-based resins (Group M, n = 108). L929 mouse fibroblasts were used as the biological model, with a negative control group (Group C, n = 36). After 24 h of cell attachment, cell viability was assessed after 72 h under two conditions: indirect exposure to resin eluates and direct contact with resin discs. Viability was quantified by crystal violet staining. Data were analyzed using Kruskal-Wallis tests followed by Dunn's pairwise post hoc comparisons (α = 0.05). RESULTS: In the indirect assay, Group M showed 87% cell survival relative to the control, whereas Group P showed 65%; in the direct assay, values were 89% and 48%, respectively. Significant differences were observed among pooled groups in both assays (p < 0.001). Based on ISO 10993-5 thresholds, Group P was classified as slightly cytotoxic in the indirect assay and moderately cytotoxic in the direct assay, whereas Group M remained within the non-cytotoxic to slightly cytotoxic range. Group P showed significantly lower cell viability than Group M in both assays (adjusted p < 0.001), while no statistically significant differences were detected within each manufacturing category (adjusted p > 0.05). CONCLUSIONS: At 72 h, the tested AM resins showed significantly lower cell viability than the tested SM PMMA-based resins under the present in vitro conditions. CLINICAL SIGNIFICANCE: The lower cell viability observed for the tested 3D-printed interim materials under short-term in vitro conditions highlights the need for caution when extrapolating 72-h cell-viability findings to clinical performance and supports further standardized long-term in vitro and in vivo investigations.

Clinical and Experimental Dental ResearchVol. 12(4)
Universidad Complutense de Madrid (ES), Shiraz University of Medical Sciences (IR), Hospital Clínico San Carlos (ES), Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (ES), Medical Research Network (US), Saveetha University (IN)
Universidad Complutense de Madrid, Shiraz University of Medical Sciences, Shiraz University
Openalex Percentile: Top 7%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.