Entropy-Based Phonocardiogram Classification Using Continuous and Synchrosqueezed Wavelet Transforms: A Systematic Comparison

Background/Objectives: Cardiac auscultation is an important method for identifying cardiovascular abnormalities, but conventional methods are limited by examiner-dependent variability and sensitivity. The automatic classification of phonocardiogram (PCG) has the potential to be applied for standardized cardiac screening, but still has to deal with signal non-stationarity and the extraction of discriminative features. This investigation develops a computational framework integrating wavelet analysis with entropy-based features for distinguishing normal and abnormal heart sounds. Methods: The study employs the PhysioNet Computing in Cardiology Challenge 2016 database. Signal processing includes resampling, zero-phase Butterworth band-pass filtering (20–800 Hz), and median absolute deviation normalization. Time–frequency representations are generated through continuous wavelet transform (CWT) and synchrosqueezed CWT using analytic Morlet wavelets. Multiple entropy measures including Shannon, Rényi, Tsallis, spectral, permutation, and sample entropies are computed globally and across four physiologically motivated frequency bands (20–80, 80–200, 200–400, 400–800 Hz). A regularized multi-layer perceptron with dropout performs classification. Evaluation employs stratified 5-fold cross-validation with recording-level partitioning to prevent data leakage. Results: The best configuration using standard CWT with 800 Hz bandwidth achieved test-set AUROC of 0.972, balanced accuracy of 0.915, and 96% sensitivity maintained at 90% specificity. Contrary to expectations, standard CWT outperformed synchrosqueezed CWT with AUROC advantage of +0.038. Also, the band-specific entropy analysis provided the largest performance contribution with +4.1% to AUROC, confirming frequency-localized pathological signatures. Conclusions: This methodology demonstrates how the conventional wavelet analysis integrated with entropy engineering achieves state-of-the-art performance. Also, it maintains computational efficiency (1.2 s extraction and classification) and interpretability, offering practical potential for point-of-care cardiac screening in resource-limited settings.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-07-16
DOI
https://doi.org/10.3390/diagnostics16142223
Primary Topic
Phonocardiography and Auscultation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Entropy-Based Phonocardiogram Classification Using Continuous and Synchrosqueezed Wavelet Transforms: A Systematic Comparison

Anupinder Singh, Mandeep Singh, Vinay Arora
Diagnostics
Phonocardiography and Auscultation Techniques
article

Entropy-Based Phonocardiogram Classification Using Continuous and Synchrosqueezed Wavelet Transforms: A Systematic Comparison

Anupinder Singh, Mandeep Singh, Vinay Arora
article en

Abstract

Background/Objectives: Cardiac auscultation is an important method for identifying cardiovascular abnormalities, but conventional methods are limited by examiner-dependent variability and sensitivity. The automatic classification of phonocardiogram (PCG) has the potential to be applied for standardized cardiac screening, but still has to deal with signal non-stationarity and the extraction of discriminative features. This investigation develops a computational framework integrating wavelet analysis with entropy-based features for distinguishing normal and abnormal heart sounds. Methods: The study employs the PhysioNet Computing in Cardiology Challenge 2016 database. Signal processing includes resampling, zero-phase Butterworth band-pass filtering (20–800 Hz), and median absolute deviation normalization. Time–frequency representations are generated through continuous wavelet transform (CWT) and synchrosqueezed CWT using analytic Morlet wavelets. Multiple entropy measures including Shannon, Rényi, Tsallis, spectral, permutation, and sample entropies are computed globally and across four physiologically motivated frequency bands (20–80, 80–200, 200–400, 400–800 Hz). A regularized multi-layer perceptron with dropout performs classification. Evaluation employs stratified 5-fold cross-validation with recording-level partitioning to prevent data leakage. Results: The best configuration using standard CWT with 800 Hz bandwidth achieved test-set AUROC of 0.972, balanced accuracy of 0.915, and 96% sensitivity maintained at 90% specificity. Contrary to expectations, standard CWT outperformed synchrosqueezed CWT with AUROC advantage of +0.038. Also, the band-specific entropy analysis provided the largest performance contribution with +4.1% to AUROC, confirming frequency-localized pathological signatures. Conclusions: This methodology demonstrates how the conventional wavelet analysis integrated with entropy engineering achieves state-of-the-art performance. Also, it maintains computational efficiency (1.2 s extraction and classification) and interpretability, offering practical potential for point-of-care cardiac screening in resource-limited settings.

DiagnosticsVol. 16(14)
Thapar Institute of Engineering & Technology (IN)
Reduced inequalities
Openalex Percentile: Top 9%
Phonocardiography and Auscultation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.