GMP‐compliant production, validation and dosimetry of clinical grade [ <sup>18</sup> F]3‐(3‐fluoropropyl)‐2‐phenyl‐2,3‐dihydrobenzo[d]thiazole ([ <sup>18</sup> F]FPBT) for oxidative stress PET imaging

Background and Purpose Oxidative stress plays a critical role in the pathophysiology of various diseases, yet current methods for its non‐invasive detection remain limited. This study aimed to systematically validate a superoxide‐selective PET tracer, [ 18 F]FPBT, for the early diagnosis and therapeutic monitoring of oxidative stress‐related conditions. Experimental Approach [ 18 F]FPBT was synthesised using a GMP‐compliant, automated production protocol on the Trasis AllinOne platform. The product underwent comprehensive quality control tests to ensure clinical suitability. Preclinical imaging was conducted using a clinical PET scanner in LPS‐ and doxorubicin‐treated rabbits, to assess tracer uptake in organs subject to oxidative stress. Radiation dosimetry was measured in healthy rabbits to estimate effective human doses. Acute toxicity was evaluated using nonradioactive FPBT in KM mice (1.875 mg·kg −1 ). Key Results [ 18 F]FPBT was successfully produced with batch yields ranging from 2.69 to 4.64 GBq when starting from 19.20–68.45 GBq of fluoride‐18. PET imaging demonstrated clear visualisation of cardiac oxidative stress in LPS‐ and doxorubicin‐treated rabbits. Estimated human radiation doses were 0.022 ± 0.004 mSv·MBq −1 for males and 0.028 ± 0.005 mSv·MBq −1 for females, comparable to [ 18 F]FDG. No treatment‐related adverse effects were observed in mice administered FBPT at a dose corresponding to 8896‐fold the projected nonradioactive mass dose for a 150‐MBq [ 18 F]FBPT PET scan in humans. Conclusions and Implications [ 18 F]FPBT meets the regulatory and biological safety criteria for human use and shows strong potential for first‐in‐human PET imaging studies. This tracer could enable early diagnosis, monitoring and treatment evaluation in cardiovascular diseases characterised by elevated oxidative stress.

Authors

Institutions

Publication Details

Journal
British Journal of Pharmacology
Published
2026-07-16
DOI
https://doi.org/10.1111/bph.70593
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

GMP‐compliant production, validation and dosimetry of clinical grade [ 18 F]3‐(3‐fluoropropyl)‐2‐phenyl‐2,3‐dihydrobenzo[d]thiazole ([ 18 F]FPBT) for oxidative stress PET imaging

Fangfang Sun, Samantha Y.A. Terry, Ran Yan, Haitao Zhang et al.
British Journal of Pharmacology
Medical Imaging Techniques and Applications
article

GMP‐compliant production, validation and dosimetry of clinical grade [ 18 F]3‐(3‐fluoropropyl)‐2‐phenyl‐2,3‐dihydrobenzo[d]thiazole ([ 18 F]FPBT) for oxidative stress PET imaging

Fangfang Sun, Samantha Y.A. Terry, Ran Yan, Haitao Zhang, Yuexuan Song, Zhi Lu, L Jiang, Paul Gape, Shujun He, Chun Li, Xin Wang
article en

Abstract

Background and Purpose Oxidative stress plays a critical role in the pathophysiology of various diseases, yet current methods for its non‐invasive detection remain limited. This study aimed to systematically validate a superoxide‐selective PET tracer, [ 18 F]FPBT, for the early diagnosis and therapeutic monitoring of oxidative stress‐related conditions. Experimental Approach [ 18 F]FPBT was synthesised using a GMP‐compliant, automated production protocol on the Trasis AllinOne platform. The product underwent comprehensive quality control tests to ensure clinical suitability. Preclinical imaging was conducted using a clinical PET scanner in LPS‐ and doxorubicin‐treated rabbits, to assess tracer uptake in organs subject to oxidative stress. Radiation dosimetry was measured in healthy rabbits to estimate effective human doses. Acute toxicity was evaluated using nonradioactive FPBT in KM mice (1.875 mg·kg −1 ). Key Results [ 18 F]FPBT was successfully produced with batch yields ranging from 2.69 to 4.64 GBq when starting from 19.20–68.45 GBq of fluoride‐18. PET imaging demonstrated clear visualisation of cardiac oxidative stress in LPS‐ and doxorubicin‐treated rabbits. Estimated human radiation doses were 0.022 ± 0.004 mSv·MBq −1 for males and 0.028 ± 0.005 mSv·MBq −1 for females, comparable to [ 18 F]FDG. No treatment‐related adverse effects were observed in mice administered FBPT at a dose corresponding to 8896‐fold the projected nonradioactive mass dose for a 150‐MBq [ 18 F]FBPT PET scan in humans. Conclusions and Implications [ 18 F]FPBT meets the regulatory and biological safety criteria for human use and shows strong potential for first‐in‐human PET imaging studies. This tracer could enable early diagnosis, monitoring and treatment evaluation in cardiovascular diseases characterised by elevated oxidative stress.

British Journal of Pharmacology
King's College London (GB), Dalian Medical University (CN), King's College School (GB), First Affiliated Hospital of Dalian Medical University (CN)
Cancer Research UK, National Institute for Health and Care Research, King's College London, King's Health Partners, Dalian Medical University, Medical Research Council, Engineering and Physical Sciences Research Council, Dalian Institute of Chemical Physics, Centre For Medical Engineering, King’s College London
Openalex Percentile: Top 8%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.