Aerodynamic effectiveness of positioning methods for conventional positive pressure ventilators operating in variable configurations

The effectiveness of mechanical tactical ventilation during rescue and firefighting operations can be improved by multiplying the number of positive pressure ventilators. Such action can shorten the time of the operation, improve its execution, and reduce the energy consumed by the ventilators used during the operation. In order to determine the proper conditions for the two ventilators to work together, tests were conducted on their positioning relative to the doorway. These values were determined from the flow parameters (flow rate and static overpressure generated). A set of conventional rotor ventilators (each with an output of 4.4 kW) was tested. The article performs an analysis of the magnitude of flow parameters depending on the setting of the positive pressure ventilator. Proper positioning of the set of ventilators can increase the flow rate through the facility by up to 32% and the pressure by 50%. The analysis conducted in the article can be used as recommendations for rescue teams for the proper selection of the setting of the positive pressure ventilator during firefighting operations of internal fires.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-07-16
DOI
https://doi.org/10.1038/s41598-026-62907-3
Primary Topic
Plasma and Flow Control in Aerodynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aerodynamic effectiveness of positioning methods for conventional positive pressure ventilators operating in variable configurations

Rafał Noske, Piotr Kaczmarzyk, Damian Bąk, Łukasz Warguła et al.
Scientific Reports
Plasma and Flow Control in Aerodynamics
article

Aerodynamic effectiveness of positioning methods for conventional positive pressure ventilators operating in variable configurations

Rafał Noske, Piotr Kaczmarzyk, Damian Bąk, Łukasz Warguła, Bartosz Ziegler, Bartosz Wieczorek, Piotr Krawiec
article en

Abstract

The effectiveness of mechanical tactical ventilation during rescue and firefighting operations can be improved by multiplying the number of positive pressure ventilators. Such action can shorten the time of the operation, improve its execution, and reduce the energy consumed by the ventilators used during the operation. In order to determine the proper conditions for the two ventilators to work together, tests were conducted on their positioning relative to the doorway. These values were determined from the flow parameters (flow rate and static overpressure generated). A set of conventional rotor ventilators (each with an output of 4.4 kW) was tested. The article performs an analysis of the magnitude of flow parameters depending on the setting of the positive pressure ventilator. Proper positioning of the set of ventilators can increase the flow rate through the facility by up to 32% and the pressure by 50%. The analysis conducted in the article can be used as recommendations for rescue teams for the proper selection of the setting of the positive pressure ventilator during firefighting operations of internal fires.

Scientific Reports
Scientific and Research Centre for Fire Protection (PL), Poznań University of Technology (PL)
Affordable and clean energy
Openalex Percentile: Top 4%
Plasma and Flow Control in Aerodynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.