A novel method for EKG anomaly detection based on the double sliding window technique

Traditional detection methods often rely on fixed thresholding or machine-learning models, which can be computationally expensive. This study introduces a double-sliding-window technique to detect anomalies in ECG signals through adaptive-signal analysis. This method uses two independent sliding windows to dynamically track signal variations, enabling real-time identification of deviations in heart rhythm without prior knowledge of data distribution. The detection module achieved an average execution-time of 0.03 seconds with using less than 16 MB of memory, supporting its suitability for real-time systems. Furthermore, confusion matrix analysis yielded an accuracy of 95.33%, a sensitivity of 95.00%, a precision of 100.00%, and a specificity of 100.00%.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2026-07-16
DOI
https://doi.org/10.1080/10255842.2026.2703741
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel method for EKG anomaly detection based on the double sliding window technique

Alejandro Díaz‐Sánchez, Rubén Salas-Cabrera, Samuel A. Torres-de-Anda, Luis F. Cisneros-Sinencio
Computer Methods in Biomechanics & Biomedical Engineering
ECG Monitoring and Analysis
article

A novel method for EKG anomaly detection based on the double sliding window technique

Alejandro Díaz‐Sánchez, Rubén Salas-Cabrera, Samuel A. Torres-de-Anda, Luis F. Cisneros-Sinencio
article en

Abstract

Traditional detection methods often rely on fixed thresholding or machine-learning models, which can be computationally expensive. This study introduces a double-sliding-window technique to detect anomalies in ECG signals through adaptive-signal analysis. This method uses two independent sliding windows to dynamically track signal variations, enabling real-time identification of deviations in heart rhythm without prior knowledge of data distribution. The detection module achieved an average execution-time of 0.03 seconds with using less than 16 MB of memory, supporting its suitability for real-time systems. Furthermore, confusion matrix analysis yielded an accuracy of 95.33%, a sensitivity of 95.00%, a precision of 100.00%, and a specificity of 100.00%.

Computer Methods in Biomechanics & Biomedical Engineering
Instituto Tecnológico de Ciudad Madero (MX), National Institute of Astrophysics, Optics and Electronics (MX)
Tecnológico Nacional de México
Openalex Percentile: Top 9%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.