Standardized synchronization and validation pipeline for physiological biomarkers across multiple devices

Wearable devices enable continuous monitoring of physiological signals in real-world settings, yet a standardized approach for synchronizing signals across devices remains lacking. We present a generalizable, user-friendly pipeline that enables synchronization of any two devices capturing the same physiological signals, without requiring coding expertise. The pipeline performs resampling, dynamic time warping alignment, amplitude correction via wavelet transforms, and signal standardization, followed by agreement analyses at both waveform and feature levels. To demonstrate its validity, we applied the pipeline to a case study comparing two research-grade devices, the Empatica E4 and the EmbracePlus, using up to 48 h of concurrent recordings from 31 participants. We compared signal-level agreement across waveform similarity, amplitude distribution, spectral content, and extracted features between the two research-grade devices to determine their interchangeability for longitudinal and multi-site studies. Specifically, we aimed to determine how well these devices agree at the signal level and to identify which physiological signals are most robust to device-specific variability. Four signals were examined (blood volume pulse, electrodermal activity, accelerometry, and temperature) using NeuroKit2 and FLIRT. We computed Pearson and concordance correlation coefficients, Bland-Altman bias and limits of agreement, root mean squared error (RMSE), KL divergence, spectral coherence, mutual information, and feature-level correlations using NeuroKit2 and FLIRT. Results showed near-perfect agreement for BVP (concordance correlation coefficient (CCC) ≈ 1.0; coherence ≤ 0.98) and phasic EDA features (CCC 0.85-0.99), whereas tonic EDA, temperature, and accelerometry exhibited systematic amplitude biases (EmbracePlus lower) and axis-dependent variability (Z-axis CCC = 0.85; Y-axis = 0.19). Relative signal dynamics were preserved across devices despite differences in absolute levels. These findings support integration of BVP, EDA, and TEMP data across E4 and EmbracePlus with proper preprocessing, while highlighting calibration needs for movement signals.

Authors

Institutions

Publication Details

Journal
Behavior Research Methods
Published
2026-07-16
DOI
https://doi.org/10.3758/s13428-026-03097-8
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Standardized synchronization and validation pipeline for physiological biomarkers across multiple devices

Diego Hidalgo‐Mazzei, Filippo Corponi, Mitra Baratchi, Bryan M. Li et al.
Behavior Research Methods
Non-Invasive Vital Sign Monitoring
article

Standardized synchronization and validation pipeline for physiological biomarkers across multiple devices

Diego Hidalgo‐Mazzei, Filippo Corponi, Mitra Baratchi, Bryan M. Li, Stefan Bogaerts, Clàudia Valenzuela‐Pascual, Selin Acan, Peter de Looff, Erno Hermans, Dick Thijssen, Martin Dresler, Gideon Vos
article en

Abstract

Wearable devices enable continuous monitoring of physiological signals in real-world settings, yet a standardized approach for synchronizing signals across devices remains lacking. We present a generalizable, user-friendly pipeline that enables synchronization of any two devices capturing the same physiological signals, without requiring coding expertise. The pipeline performs resampling, dynamic time warping alignment, amplitude correction via wavelet transforms, and signal standardization, followed by agreement analyses at both waveform and feature levels. To demonstrate its validity, we applied the pipeline to a case study comparing two research-grade devices, the Empatica E4 and the EmbracePlus, using up to 48 h of concurrent recordings from 31 participants. We compared signal-level agreement across waveform similarity, amplitude distribution, spectral content, and extracted features between the two research-grade devices to determine their interchangeability for longitudinal and multi-site studies. Specifically, we aimed to determine how well these devices agree at the signal level and to identify which physiological signals are most robust to device-specific variability. Four signals were examined (blood volume pulse, electrodermal activity, accelerometry, and temperature) using NeuroKit2 and FLIRT. We computed Pearson and concordance correlation coefficients, Bland-Altman bias and limits of agreement, root mean squared error (RMSE), KL divergence, spectral coherence, mutual information, and feature-level correlations using NeuroKit2 and FLIRT. Results showed near-perfect agreement for BVP (concordance correlation coefficient (CCC) ≈ 1.0; coherence ≤ 0.98) and phasic EDA features (CCC 0.85-0.99), whereas tonic EDA, temperature, and accelerometry exhibited systematic amplitude biases (EmbracePlus lower) and axis-dependent variability (Z-axis CCC = 0.85; Y-axis = 0.19). Relative signal dynamics were preserved across devices despite differences in absolute levels. These findings support integration of BVP, EDA, and TEMP data across E4 and EmbracePlus with proper preprocessing, while highlighting calibration needs for movement signals.

Behavior Research MethodsVol. 58(8)
Leiden University (NL), Radboud University Nijmegen (NL), Tilburg University (NL), Instituto de Salud Carlos III (ES), Radboud University Medical Center (NL), Ipse de Bruggen (NL), Radboud Institute for Molecular Life Sciences (NL), Hospital Clínic de Barcelona (ES), Consorci Institut D'Investigacions Biomediques August Pi I Sunyer (ES), Medical Research Network (US), Universitat de Barcelona (ES), James Cook University (AU), Rotterdam University of Applied Sciences (NL), University of Edinburgh (GB)
Openalex Percentile: Top 16%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.