Antibody-Free SPR Detection of Human Myoglobin in Serum by a Sandwich Configuration of Epitope-Imprinted Nanofilms and Nanoparticles

High Resolution Image Download MS PowerPoint Slide Designing robust, fully synthetic receptors capable of selective protein detection remains critical for advanced clinical diagnostics. Molecularly imprinted polymers (MIPs) are a promising alternative to antibodies, but their application is often limited by empirical epitope selection and incomplete integration into functional assays. Here, we present an end-to-end platform combining data-driven epitope selection with polynorepinephrine-based molecular imprinting to produce fully synthetic protein receptors. The Python script “Epitope Selection Rational Approach” (ESRA), integrating physicochemical descriptor analysis and supervised machine learning, was developed and applied to human myoglobin (MYG) to identify effective imprintable peptide epitopes in the pre-analytical stage. Five selected epitopes were used to fabricate molecularly imprinted PNE nanofilms (MIPNE-NFs) and nanoparticles (MIPNE-NPs), targeting distinct regions of MYG. Systematic kinetic and affinity characterization by surface plasmon resonance (SPR) revealed pronounced epitope- and format-dependent recognition, underscoring the need for parallel evaluation of nanofilm and nanoparticle architectures. The optimal NF/NP combination, exploited as a capturing probe and a signal enhancer, respectively, was implemented in a fully antibody-free SPR sandwich assay. This configuration achieved sensitive detection over 4–125 ng mL –1, with a limit of detection of 0.9 ± 0.5 ng mL –1 in buffer and 0.70 ± 0.02 ng mL –1 in 1/200 diluted serum, covering the clinically relevant range for acute myocardial infarction, rhabdomyolysis, and muscle injury. This work establishes a generalizable workflow, from rational epitope selection to imprinting, kinetic validation, and assay integration, demonstrating that MIPNE can provide robust, antibody-free alternatives for sensitive protein detection in complex biological matrices.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2026-07-16
DOI
https://doi.org/10.1021/acssensors.6c01540
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Antibody-Free SPR Detection of Human Myoglobin in Serum by a Sandwich Configuration of Epitope-Imprinted Nanofilms and Nanoparticles

Simona Scarano, Maria Minunni, Pasquale Palladino, Davide Sestaioni et al.
ACS Sensors
Analytical chemistry methods development
article

Antibody-Free SPR Detection of Human Myoglobin in Serum by a Sandwich Configuration of Epitope-Imprinted Nanofilms and Nanoparticles

Simona Scarano, Maria Minunni, Pasquale Palladino, Davide Sestaioni, Andrea Barucci, Giulia Ciacci, Simone Ventisette
article en

Abstract

High Resolution Image Download MS PowerPoint Slide Designing robust, fully synthetic receptors capable of selective protein detection remains critical for advanced clinical diagnostics. Molecularly imprinted polymers (MIPs) are a promising alternative to antibodies, but their application is often limited by empirical epitope selection and incomplete integration into functional assays. Here, we present an end-to-end platform combining data-driven epitope selection with polynorepinephrine-based molecular imprinting to produce fully synthetic protein receptors. The Python script “Epitope Selection Rational Approach” (ESRA), integrating physicochemical descriptor analysis and supervised machine learning, was developed and applied to human myoglobin (MYG) to identify effective imprintable peptide epitopes in the pre-analytical stage. Five selected epitopes were used to fabricate molecularly imprinted PNE nanofilms (MIPNE-NFs) and nanoparticles (MIPNE-NPs), targeting distinct regions of MYG. Systematic kinetic and affinity characterization by surface plasmon resonance (SPR) revealed pronounced epitope- and format-dependent recognition, underscoring the need for parallel evaluation of nanofilm and nanoparticle architectures. The optimal NF/NP combination, exploited as a capturing probe and a signal enhancer, respectively, was implemented in a fully antibody-free SPR sandwich assay. This configuration achieved sensitive detection over 4–125 ng mL –1, with a limit of detection of 0.9 ± 0.5 ng mL –1 in buffer and 0.70 ± 0.02 ng mL –1 in 1/200 diluted serum, covering the clinically relevant range for acute myocardial infarction, rhabdomyolysis, and muscle injury. This work establishes a generalizable workflow, from rational epitope selection to imprinting, kinetic validation, and assay integration, demonstrating that MIPNE can provide robust, antibody-free alternatives for sensitive protein detection in complex biological matrices.

ACS Sensors
University of Pisa (IT), Nello Carrara Institute of Applied Physics (IT), University of Florence (IT)
Dipartimenti di Eccellenza, European Commission, Ministero dell’Istruzione, dell’Università e della Ricerca, Università degli Studi di Firenze, NextGenerationEU
Openalex Percentile: Top 13%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.