Determining lower and upper bounds for active power calculated from synchronized measurements in system integrity protection applications

Synchronized phasor measurements have emerged as a crucial element in the design of modern System Integrity Protection Schemes (SIPSs). However, the design of these schemes often overlooks the intrinsic measurement inaccuracies introduced by the complete instrumentation channels (ICs), specifically the inaccuracies originating from voltage and current transformers, control cables, equipment burden, and the synchrophasor estimation process. This paper proposes an optimization-based approach to determine the lower and upper bounds for active power calculated using synchronized voltage and current measurements, supporting consistent parameterization of synchrophasor-based protection strategies. Numerical results are generated using synthetic data parameterized by the IC characteristics of a pilot Wide-Area Monitoring, Protection, and Control (WAMPAC) design in Brazil, providing quantitative guidance for establishing reliable SIPS arming parametrization.

Authors

Institutions

Publication Details

Journal
Electric Power Systems Research
Published
2026-07-16
DOI
https://doi.org/10.1016/j.epsr.2026.113759
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determining lower and upper bounds for active power calculated from synchronized measurements in system integrity protection applications

Ulisses Chemin Netto, Diego Issicaba, Raul Torres Bernardo, Guido R. Moraes et al.
Electric Power Systems Research
Power System Optimization and Stability
article

Determining lower and upper bounds for active power calculated from synchronized measurements in system integrity protection applications

Ulisses Chemin Netto, Diego Issicaba, Raul Torres Bernardo, Guido R. Moraes, Antonio F. C. Aquino, Bryan A.S. Ambrósio, Augusto Tietz, Osvalter P. Filho, Paulo Zerbati, José C.S. Junior
article en

Abstract

Synchronized phasor measurements have emerged as a crucial element in the design of modern System Integrity Protection Schemes (SIPSs). However, the design of these schemes often overlooks the intrinsic measurement inaccuracies introduced by the complete instrumentation channels (ICs), specifically the inaccuracies originating from voltage and current transformers, control cables, equipment burden, and the synchrophasor estimation process. This paper proposes an optimization-based approach to determine the lower and upper bounds for active power calculated using synchronized voltage and current measurements, supporting consistent parameterization of synchrophasor-based protection strategies. Numerical results are generated using synthetic data parameterized by the IC characteristics of a pilot Wide-Area Monitoring, Protection, and Control (WAMPAC) design in Brazil, providing quantitative guidance for establishing reliable SIPS arming parametrization.

Electric Power Systems ResearchVol. 264
Universidade Tecnológica Federal do Paraná (BR), State Grid Corporation of China (China) (CN), Universidade Federal de Santa Catarina (BR), Inesc P&D Brasil (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico
Openalex Percentile: Top 15%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.