PolypSAM-Open: Mitigating Automation Bias in AI-Assisted Colonoscopy via Open-Set Surgical Artifact Rejection

Background: Intelligent decision support systems for colonoscopy can fail when encountering out-of-distribution surgical instruments such as snares or biopsy forceps, producing false-positive polyp masks that may contribute to automation bias and reduce workflow reliability. This study aimed to develop and evaluate a parameter-efficient framework for open-set-aware polyp segmentation that can reject such anomalous inputs while preserving in-distribution segmentation performance. Methods: We propose PolypSAM-Open, which integrates a prototype-based Open-Set Learning (OSL) module with Low-Rank Adaptation (LoRA) in the MedSAM image encoder. The model was trained on Kvasir-SEG using an 85/15 split of authentic polyp images and synthetic high-frequency Gaussian noise to learn a rejection margin. Zero-shot out-of-distribution detection was evaluated on 590 unseen authentic surgical instruments from Kvasir-Instrument. Segmentation and detection performance were compared against a standard MedSAM-LoRA baseline. Results: Standard parameter-efficient fine-tuning yielded an OOD AUROC of 0.4263 on authentic surgical instruments. PolypSAM-Open improved zero-shot OOD AUROC to 0.9535 (p<0.001). Despite allocating 15% of training capacity to the synthetic-noise rejection margin, PolypSAM-Open maintained segmentation performance comparable to the standard fine-tuned baseline (Dice 0.9728 versus 0.9723). On ETIS-LaribPolypDB and CVC-ClinicDB, Dice scores were 0.9301 and 0.9386, respectively. The approach remained parameter-efficient, updating 4.48% of total parameters while adding negligible inference latency relative to the underlying MedSAM forward. Conclusions: Prototype-based open-set adaptation can substantially improve rejection of unseen surgical artifacts in AI-assisted colonoscopy while preserving high segmentation accuracy. These findings position PolypSAM-Open as a promising strategy for potentially safer decision-support segmentation in endoscopic workflows; prospective clinical validation remains necessary.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-07-16
DOI
https://doi.org/10.3390/diagnostics16142226
Primary Topic
Colorectal Cancer Screening and Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PolypSAM-Open: Mitigating Automation Bias in AI-Assisted Colonoscopy via Open-Set Surgical Artifact Rejection

Sifat Momen, Shadman Shahriar, Muhammad Martuza, † Hossain et al.
Diagnostics
Colorectal Cancer Screening and Detection
article

PolypSAM-Open: Mitigating Automation Bias in AI-Assisted Colonoscopy via Open-Set Surgical Artifact Rejection

Sifat Momen, Shadman Shahriar, Muhammad Martuza, † Hossain, Umar Hasan, Faiyad Hossain
article en

Abstract

Background: Intelligent decision support systems for colonoscopy can fail when encountering out-of-distribution surgical instruments such as snares or biopsy forceps, producing false-positive polyp masks that may contribute to automation bias and reduce workflow reliability. This study aimed to develop and evaluate a parameter-efficient framework for open-set-aware polyp segmentation that can reject such anomalous inputs while preserving in-distribution segmentation performance. Methods: We propose PolypSAM-Open, which integrates a prototype-based Open-Set Learning (OSL) module with Low-Rank Adaptation (LoRA) in the MedSAM image encoder. The model was trained on Kvasir-SEG using an 85/15 split of authentic polyp images and synthetic high-frequency Gaussian noise to learn a rejection margin. Zero-shot out-of-distribution detection was evaluated on 590 unseen authentic surgical instruments from Kvasir-Instrument. Segmentation and detection performance were compared against a standard MedSAM-LoRA baseline. Results: Standard parameter-efficient fine-tuning yielded an OOD AUROC of 0.4263 on authentic surgical instruments. PolypSAM-Open improved zero-shot OOD AUROC to 0.9535 (p<0.001). Despite allocating 15% of training capacity to the synthetic-noise rejection margin, PolypSAM-Open maintained segmentation performance comparable to the standard fine-tuned baseline (Dice 0.9728 versus 0.9723). On ETIS-LaribPolypDB and CVC-ClinicDB, Dice scores were 0.9301 and 0.9386, respectively. The approach remained parameter-efficient, updating 4.48% of total parameters while adding negligible inference latency relative to the underlying MedSAM forward. Conclusions: Prototype-based open-set adaptation can substantially improve rejection of unseen surgical artifacts in AI-assisted colonoscopy while preserving high segmentation accuracy. These findings position PolypSAM-Open as a promising strategy for potentially safer decision-support segmentation in endoscopic workflows; prospective clinical validation remains necessary.

DiagnosticsVol. 16(14)
Qassim University (SA), North South University (BD)
Qassim University
Peace, Justice and strong institutions
Openalex Percentile: Top 11%
Colorectal Cancer Screening and Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.