Detection and localization of posterior circulation large vessel occlusions using perfusion imaging

BACKGROUND AND PURPOSE: Cerebral perfusion imaging may help detect the presence of, and infer vessel occlusion location in, anterior circulation stroke, but its value in posterior circulation large vessel occlusion (PC-LVO) is less well defined. We evaluated the accuracy and inter-reader reliability of CT and MR perfusion imaging for occlusion classification and posterior circulation vessel localization. METHODS: We performed a retrospective multicenter diagnostic accuracy study from 11 centers that underwent perfusion imaging for stroke evaluation. The cohort was enriched for posterior circulation stroke. Four blinded readers assigned each case to one of five categories: no occlusion, anterior circulation large vessel occlusion (AC-LVO), basilar artery, posterior cerebral artery (PCA), or vertebral/posterior inferior cerebellar artery (vert/PICA) occlusion. Final classification was determined by majority vote. RESULTS: 184 patients were included. Perfusion imaging correctly classified 150/184 cases on the 5-class task (81.5%, 95% CI 75.1% to 86.9%). Across the 3-class task of LVO(-), AC-LVO, and PC-LVO, accuracy was 163/184 (88.6%, 95% CI 83.1% to 92.8%), with sensitivity of 100% for LVO(-), 100% for AC-LVO, and 84.4% for PC-LVO. Within the posterior circulation subgroup, perfusion imaging correctly localized basilar, PCA, and vert/PICA occlusions in 101/135 cases (74.8%, 95% CI 66.6% to 81.9%), including 82/107 basilar (76.6%), 10/12 PCA (83.3%), and 9/16 vert/PICA (56.3%). Fleiss κ was 0.889 for the 3-class task, 0.742 for the 5-class task, and 0.604 for posterior localization. CONCLUSION: Perfusion imaging is moderately accurate for the detection and localization of PC-LVO, but performs less well compared with the detection of AC-LVO.

Authors

Institutions

Publication Details

Journal
Journal of NeuroInterventional Surgery
Published
2026-07-16
DOI
https://doi.org/10.1136/jnis-2026-025637
Primary Topic
Acute Ischemic Stroke Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection and localization of posterior circulation large vessel occlusions using perfusion imaging

Maarten G. Lansberg, Jeremy Josef Heit, Seena Dehkharghani, Tobias Djamsched Faizy et al.
Journal of NeuroInterventional Surgery
Acute Ischemic Stroke Management
article

Detection and localization of posterior circulation large vessel occlusions using perfusion imaging

Maarten G. Lansberg, Jeremy Josef Heit, Seena Dehkharghani, Tobias Djamsched Faizy, Michael Mlynash, Ish Talati, G D Albers, Lieselotte Vandewalle, Vivek Srikar Yedavalli, Samantha Rhodes, Maya Schwartz, Benci Zeno, Pierre Seners, Nicole Yuen, Carlo W Cereda
article en

Abstract

BACKGROUND AND PURPOSE: Cerebral perfusion imaging may help detect the presence of, and infer vessel occlusion location in, anterior circulation stroke, but its value in posterior circulation large vessel occlusion (PC-LVO) is less well defined. We evaluated the accuracy and inter-reader reliability of CT and MR perfusion imaging for occlusion classification and posterior circulation vessel localization. METHODS: We performed a retrospective multicenter diagnostic accuracy study from 11 centers that underwent perfusion imaging for stroke evaluation. The cohort was enriched for posterior circulation stroke. Four blinded readers assigned each case to one of five categories: no occlusion, anterior circulation large vessel occlusion (AC-LVO), basilar artery, posterior cerebral artery (PCA), or vertebral/posterior inferior cerebellar artery (vert/PICA) occlusion. Final classification was determined by majority vote. RESULTS: 184 patients were included. Perfusion imaging correctly classified 150/184 cases on the 5-class task (81.5%, 95% CI 75.1% to 86.9%). Across the 3-class task of LVO(-), AC-LVO, and PC-LVO, accuracy was 163/184 (88.6%, 95% CI 83.1% to 92.8%), with sensitivity of 100% for LVO(-), 100% for AC-LVO, and 84.4% for PC-LVO. Within the posterior circulation subgroup, perfusion imaging correctly localized basilar, PCA, and vert/PICA occlusions in 101/135 cases (74.8%, 95% CI 66.6% to 81.9%), including 82/107 basilar (76.6%), 10/12 PCA (83.3%), and 9/16 vert/PICA (56.3%). Fleiss κ was 0.889 for the 3-class task, 0.742 for the 5-class task, and 0.604 for posterior localization. CONCLUSION: Perfusion imaging is moderately accurate for the detection and localization of PC-LVO, but performs less well compared with the detection of AC-LVO.

Journal of NeuroInterventional Surgery
Johns Hopkins University (US), University of Münster (DE), Laboratory for Biomedical Neurosciences (CH), Fondation de Rothschild (FR), Stanford Medicine (US), FH Münster University of Applied Sciences (DE), Stanford University (US), KU Leuven (BE)
Good health and well-being
Openalex Percentile: Top 8%
Acute Ischemic Stroke Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.