The Clinical Value of Distinguishing Benign and Malignant Thyroid Micronodules With Intratumoral and Peritumoral CT Radiomic Models

OBJECTIVE: To study the utility of intratumoral and peritumoral radiomic models in distinguishing between benign and malignant thyroid micronodules. METHODS: CT-enhanced images of 607 patients with thyroid micronodules were obtained, and an additional 100 patients with micronodules were collected as an independent test group on the basis of the sequence of their examination times. The peritumoral region of interest (ROI) was delineated by expanding outward by 1 and 2 mm. Radiomics features were extracted from the 3-dimensional volume of interest (VOI), which included intratumoral, peritumoral 1 mm, peritumoral 2 mm, intratumoral+peritumoral 1 mm and 2 mm in the arterial phase, venous phase, and combined arteriovenous phase. All of the data were randomly divided into training and validation groups at an 8:2 ratio. The minimum redundancy maximum relevance (mRMR) and the least absolute shrinkage and selection operator (LASSO) method was utilized for regression dimension reduction. Radscore, clinical, and combined models were constructed. A nomogram was used to assess the performance of the fusion model, and an external test group was utilized to test the model's performance. RESULTS: The intratumoral+peritumoral 1 mm radiomic model based on arterial-venous phase fusion had the best prediction performance (AUC training group 0.838; 95% CI: 0.802-0.873; validation group 0.827; 95% CI: 0.755-0.899; external test group 0.770; 95% CI: 0675-0.864). The combined model constructed with the radscore and clinical model was the optimal model (AUC training group 0.859; 95% CI: 0.826-0.892; validation group 0.876; 95% CI: 0817-0.935; external test group 0.810; 95% CI: 0.723-0.897). CONCLUSION: Both the intratumoral and peritumoral radiomic models had good diagnostic efficacy in differentiating benign and malignant thyroid micronodules.

Authors

Institutions

Publication Details

Journal
Journal of Computer Assisted Tomography
Published
2026-07-16
DOI
https://doi.org/10.1097/rct.0000000000001909
Primary Topic
Thyroid Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Clinical Value of Distinguishing Benign and Malignant Thyroid Micronodules With Intratumoral and Peritumoral CT Radiomic Models

Yingying Zhuang, Lili Guo, Dan Kong, Wenli Shan et al.
Journal of Computer Assisted Tomography
Thyroid Cancer Diagnosis and Treatment
article

The Clinical Value of Distinguishing Benign and Malignant Thyroid Micronodules With Intratumoral and Peritumoral CT Radiomic Models

Yingying Zhuang, Lili Guo, Dan Kong, Wenli Shan, Yan Zeng, Fen Wang
article en

Abstract

OBJECTIVE: To study the utility of intratumoral and peritumoral radiomic models in distinguishing between benign and malignant thyroid micronodules. METHODS: CT-enhanced images of 607 patients with thyroid micronodules were obtained, and an additional 100 patients with micronodules were collected as an independent test group on the basis of the sequence of their examination times. The peritumoral region of interest (ROI) was delineated by expanding outward by 1 and 2 mm. Radiomics features were extracted from the 3-dimensional volume of interest (VOI), which included intratumoral, peritumoral 1 mm, peritumoral 2 mm, intratumoral+peritumoral 1 mm and 2 mm in the arterial phase, venous phase, and combined arteriovenous phase. All of the data were randomly divided into training and validation groups at an 8:2 ratio. The minimum redundancy maximum relevance (mRMR) and the least absolute shrinkage and selection operator (LASSO) method was utilized for regression dimension reduction. Radscore, clinical, and combined models were constructed. A nomogram was used to assess the performance of the fusion model, and an external test group was utilized to test the model's performance. RESULTS: The intratumoral+peritumoral 1 mm radiomic model based on arterial-venous phase fusion had the best prediction performance (AUC training group 0.838; 95% CI: 0.802-0.873; validation group 0.827; 95% CI: 0.755-0.899; external test group 0.770; 95% CI: 0675-0.864). The combined model constructed with the radscore and clinical model was the optimal model (AUC training group 0.859; 95% CI: 0.826-0.892; validation group 0.876; 95% CI: 0817-0.935; external test group 0.810; 95% CI: 0.723-0.897). CONCLUSION: Both the intratumoral and peritumoral radiomic models had good diagnostic efficacy in differentiating benign and malignant thyroid micronodules.

Journal of Computer Assisted Tomography
Huaian First People’s Hospital (CN), United Imaging Healthcare (China) (CN)
Beijing Medical Award Foundation
Openalex Percentile: Top 9%
Thyroid Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.