3D-printed full-arch denture teeth: impact of printing orientation on the trueness and precision in vitro

BACKGROUND: 3D-printed dentures can be fabricated by bonding two separately printed units; a base and a full-arch denture teeth. The accuracy of 3D-printed resin can be influenced by print orientation. While previous studies explored the accuracy of denture bases, no studies evaluated the accuracy of printed denture teeth in a full-arch form or the accuracy when printed at different print orientations. Therefore, this in vitro study aimed to evaluate and compare the trueness and precision of 3D-printed full-arch denture teeth fabricated with different printing orientations. METHODS: A digitally designed full-arch denture teeth model was printed using two types of 3D-printed teeth resin (ASIGA DentaTOOTH and NextDent C&B MFH) at three printing orientations (0°, 45°, and 90°). The printed specimens were scanned and compared to the original CAD design to assess trueness. Precision was evaluated by superimposing scans of identical prints. Root mean square (RMS) values were calculated to quantify deviations. Statistical analysis was conducted using ANOVA and Tukeys' post hoc tests (α = 0.05). RESULTS: Trueness was significantly influenced by printing orientation (P < 0.05). Both resins showed the highest trueness at 0°, with significantly higher accuracy in ridge-lap and axial areas (P < 0.05). Precision remained relatively stable across orientations for NextDent; however, significantly higher precision was observed at 0° orientation for ASIGA resin (P < 0.05). CONCLUSION: Printing orientation and material type influenced the accuracy of 3D‑printed full‑arch denture teeth. The 0° orientation showed the lowest deviations, with trueness ranging from 51 to 92 μm and precision from 25 to 98 μm, depending on material and region. Higher deviations were observed at 45° and 90° (up to 171-299 μm for trueness and 201-217 μm for precision), yet all values remained within laboratory‑based acceptable ranges.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-07-16
DOI
https://doi.org/10.1186/s12903-026-09242-1
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D-printed full-arch denture teeth: impact of printing orientation on the trueness and precision in vitro

Mohammed M. Gad, Reem Abualsaud, Haidar Alalawi, Danah F. Almaskin et al.
BMC Oral Health
Dental materials and restorations
article

3D-printed full-arch denture teeth: impact of printing orientation on the trueness and precision in vitro

Mohammed M. Gad, Reem Abualsaud, Haidar Alalawi, Danah F. Almaskin, Ahmad M. Al-Thobity, Ashwin C Shetty
article en

Abstract

BACKGROUND: 3D-printed dentures can be fabricated by bonding two separately printed units; a base and a full-arch denture teeth. The accuracy of 3D-printed resin can be influenced by print orientation. While previous studies explored the accuracy of denture bases, no studies evaluated the accuracy of printed denture teeth in a full-arch form or the accuracy when printed at different print orientations. Therefore, this in vitro study aimed to evaluate and compare the trueness and precision of 3D-printed full-arch denture teeth fabricated with different printing orientations. METHODS: A digitally designed full-arch denture teeth model was printed using two types of 3D-printed teeth resin (ASIGA DentaTOOTH and NextDent C&B MFH) at three printing orientations (0°, 45°, and 90°). The printed specimens were scanned and compared to the original CAD design to assess trueness. Precision was evaluated by superimposing scans of identical prints. Root mean square (RMS) values were calculated to quantify deviations. Statistical analysis was conducted using ANOVA and Tukeys' post hoc tests (α = 0.05). RESULTS: Trueness was significantly influenced by printing orientation (P < 0.05). Both resins showed the highest trueness at 0°, with significantly higher accuracy in ridge-lap and axial areas (P < 0.05). Precision remained relatively stable across orientations for NextDent; however, significantly higher precision was observed at 0° orientation for ASIGA resin (P < 0.05). CONCLUSION: Printing orientation and material type influenced the accuracy of 3D‑printed full‑arch denture teeth. The 0° orientation showed the lowest deviations, with trueness ranging from 51 to 92 μm and precision from 25 to 98 μm, depending on material and region. Higher deviations were observed at 45° and 90° (up to 171-299 μm for trueness and 201-217 μm for precision), yet all values remained within laboratory‑based acceptable ranges.

BMC Oral Health
Imam Abdulrahman Bin Faisal University (SA)
Openalex Percentile: Top 8%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.