Heat exchanger network optimization and cleaning scheduling under fouling: Application to UHT dairy processing

Heat exchanger network (HEN) performance in dairy processing plants is strongly affected by fouling and cleaning-related production interruptions, yet network design and cleaning scheduling are commonly treated separately. This work develops a two-step mixed integer nonlinear programming framework that couples utility-substage HEN synthesis with fouling-aware exchanger sizing and event-based production, aseptic intermediate cleaning (AIC), and cleaning-in-place (CIP) scheduling. The framework is adapted and demonstrated through an industrially relevant ultra-high-temperature (UHT) whole-milk case study. In Step 1, exchanger topology, utility placement, and heat transfer area are optimized under clean and fully fouled conditions. In Step 2, the selected topology is retained while exchanger areas are reoptimized jointly with the production and cleaning schedule over a one-week operating horizon. For the baseline case, the required heat-transfer area approximately doubles from 370 m 2 under clean conditions to 744 m 2 under fully fouled conditions, while dynamic scheduling results in intermediate areas of 612–656 m 2 across the cleaning-policy scenarios. The OneStep technology reduces combined external utility duty from 525 to 425 kW and lowers total annualized cost despite requiring additional exchanger area. Reducing AIC fouling removal after 1 h from 65% to 45% decreases production share from 84.3% to 80.0% and profit by 6.1%, demonstrating the operational and economic importance of cleaning effectiveness. The proposed framework provides an industrially applicable approach for integrating HEN design, fouling development, cleaning strategy, and operational economics under realistic UHT process constraints.

Authors

Institutions

Publication Details

Journal
Applied Thermal Engineering
Published
2026-11-26
DOI
https://doi.org/10.1016/j.applthermaleng.2026.134112
Primary Topic
Process Optimization and Integration
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Heat exchanger network optimization and cleaning scheduling under fouling: Application to UHT dairy processing

Dragana Arlov, Martin Andersson, Hamid Ghanbari, Xin Bin
Applied Thermal Engineering
Process Optimization and Integration
article

Heat exchanger network optimization and cleaning scheduling under fouling: Application to UHT dairy processing

Dragana Arlov, Martin Andersson, Hamid Ghanbari, Xin Bin
article en

Abstract

Heat exchanger network (HEN) performance in dairy processing plants is strongly affected by fouling and cleaning-related production interruptions, yet network design and cleaning scheduling are commonly treated separately. This work develops a two-step mixed integer nonlinear programming framework that couples utility-substage HEN synthesis with fouling-aware exchanger sizing and event-based production, aseptic intermediate cleaning (AIC), and cleaning-in-place (CIP) scheduling. The framework is adapted and demonstrated through an industrially relevant ultra-high-temperature (UHT) whole-milk case study. In Step 1, exchanger topology, utility placement, and heat transfer area are optimized under clean and fully fouled conditions. In Step 2, the selected topology is retained while exchanger areas are reoptimized jointly with the production and cleaning schedule over a one-week operating horizon. For the baseline case, the required heat-transfer area approximately doubles from 370 m 2 under clean conditions to 744 m 2 under fully fouled conditions, while dynamic scheduling results in intermediate areas of 612–656 m 2 across the cleaning-policy scenarios. The OneStep technology reduces combined external utility duty from 525 to 425 kW and lowers total annualized cost despite requiring additional exchanger area. Reducing AIC fouling removal after 1 h from 65% to 45% decreases production share from 84.3% to 80.0% and profit by 6.1%, demonstrating the operational and economic importance of cleaning effectiveness. The proposed framework provides an industrially applicable approach for integrating HEN design, fouling development, cleaning strategy, and operational economics under realistic UHT process constraints.

Applied Thermal EngineeringVol. 311
Lund University (SE), Tetra Pak (Sweden) (SE)
Responsible consumption and production, Affordable and clean energy, Industry, innovation and infrastructure
Process Optimization and Integration
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.