Improving the Clinical Utility of Lower-Limb Surface Electromyography (sEMG) by Quantifying and Correcting for Location Changes in Inter-Session Recordings

PURPOSE: Surface electromyography (sEMG) can enable direct muscle activity measurement to support the recovery assessment of individuals with neurological and musculoskeletal disorders. Despite this, its broader adoption of sEMG has been limited given its sensitivity to changes in electrode location across sessions. To address this challenge and enable multi-session sEMG, this work develops a novel high-density sEMG (HDsEMG) algorithm to quantify changes in electrode location and mitigate its effects on common time and frequency domain sEMG features. METHODS: 11 healthy participants performed isometric and dynamic exercises with HDsEMG on four lower-limb muscles. These were repeated four times, reapplying arrays at shifted locations. The error between spatially-mapped HDsEMG metrics was then minimised to estimate the change in array location, with this compared against ground truth 3D scans. Lastly, relative feature differences across locations were computed at select electrodes to assess the degree to which inter-session sEMG effects were mitigated. RESULTS: Electrode location estimates were improved over the assumption their location remained unchanged in 81.7% of cases, 37.6% identified within 1 cm of the ground truth. Feature differences computed between closest electrodes across locations per ground truth and algorithm estimates were statistically similar. Conversely, feature differences for the same electrode across locations were significantly greater, increasing the mean difference for the isometric max envelope amplitude from 15.9% with the algorithm to 21.1% without. CONCLUSIONS: The application of our algorithm effectively reduced inter-session feature differences arising from changes in electrode location. This approach can facilitate more direct cross-session feature comparisons, representing a promising step toward robust sEMG measurement for musculoskeletal and neurological recovery tracking.

Authors

Institutions

Publication Details

Journal
Annals of Biomedical Engineering
Published
2026-10-26
DOI
https://doi.org/10.1007/s10439-026-04431-z
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving the Clinical Utility of Lower-Limb Surface Electromyography (sEMG) by Quantifying and Correcting for Location Changes in Inter-Session Recordings

Fraser Douglas, Calvin Kuo, Mona Pei, Linh Le et al.
1 links
Annals of Biomedical Engineering
Muscle activation and electromyography studies
article

Improving the Clinical Utility of Lower-Limb Surface Electromyography (sEMG) by Quantifying and Correcting for Location Changes in Inter-Session Recordings

Fraser Douglas, Calvin Kuo, Mona Pei, Linh Le, Quoc Sy Vu
article en

Abstract

PURPOSE: Surface electromyography (sEMG) can enable direct muscle activity measurement to support the recovery assessment of individuals with neurological and musculoskeletal disorders. Despite this, its broader adoption of sEMG has been limited given its sensitivity to changes in electrode location across sessions. To address this challenge and enable multi-session sEMG, this work develops a novel high-density sEMG (HDsEMG) algorithm to quantify changes in electrode location and mitigate its effects on common time and frequency domain sEMG features. METHODS: 11 healthy participants performed isometric and dynamic exercises with HDsEMG on four lower-limb muscles. These were repeated four times, reapplying arrays at shifted locations. The error between spatially-mapped HDsEMG metrics was then minimised to estimate the change in array location, with this compared against ground truth 3D scans. Lastly, relative feature differences across locations were computed at select electrodes to assess the degree to which inter-session sEMG effects were mitigated. RESULTS: Electrode location estimates were improved over the assumption their location remained unchanged in 81.7% of cases, 37.6% identified within 1 cm of the ground truth. Feature differences computed between closest electrodes across locations per ground truth and algorithm estimates were statistically similar. Conversely, feature differences for the same electrode across locations were significantly greater, increasing the mean difference for the isometric max envelope amplitude from 15.9% with the algorithm to 21.1% without. CONCLUSIONS: The application of our algorithm effectively reduced inter-session feature differences arising from changes in electrode location. This approach can facilitate more direct cross-session feature comparisons, representing a promising step toward robust sEMG measurement for musculoskeletal and neurological recovery tracking.

Annals of Biomedical Engineering
University of British Columbia (CA), Douglas College (CA), Centre for Aging SMART (CA)
AGE-WELL, Canada Foundation for Innovation, Michael Smith Health Research BC, Mitacs, Natural Sciences and Engineering Research Council of Canada
Good health and well-being
Openalex Percentile: Top 61%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon