Calibration of DOI-capable PET detector panels using uncollimated front-face irradiation

OBJECTIVE: Gold-standard depth-of-interaction (DOI) calibration using collimated gamma-ray irradiation is time-consuming and requires complex experimental setups, making it impractical for system-level calibration of detector arrays. This work investigates an efficient method for DOI and energy calibration of detector panels using uncollimated irradiation, in which gamma rays are incident parallel, or nearly parallel, to the crystal depth direction. Approach. The 511-keV photopeak location on a dual-ended readout PET detector block as a function of crystal depth was first evaluated using both collimated and uncollimated 22Na source irradiation to determine whether the latter yields comparable estimates when DOI calibration parameters are known. A 4 × 4 dual-ended readout PET detector panel was then assembled, and three detector blocks were calibrated using the gold-standard method. Two DOI calibration approaches based on uncollimated irradiation-a physics-informed model and a multilayer perceptron (MLP)-were compared against the gold-standard calibration. Finally, the detector panel was calibrated for DOI and energy using the MLP-based approach. Main Results. The median relative root mean squared error (RMSE) between second-order polynomial fits to the depth-dependent photopeak location obtained using collimated and uncollimated irradiation was 1%, demonstrating that uncollimated irradiation provides reliable estimates when accurate DOI calibration parameters are available. The RMSE between the gold-standard DOI calibration and the physics-informed and MLP-based approaches ranged from 0.38-0.58 mm and 0.36-0.61 mm, respectively, with no statistically significant difference. However, DOI resolution estimates from the MLP-based approach outperformed those of the physics-informed model, favouring its use for full detector panel calibration. After saturation correction, the detector panel achieved a mean energy resolution of 15.6% and a DOI resolution of 2.0 mm. Significance. The proposed MLP-based calibration requires only a single uniform 511-keV source irradiation, making it simple to implement and sufficiently robust for in situ calibration of DOI-capable PET detector arrays.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-08-21
DOI
https://doi.org/10.1088/1361-6560/ae9d12
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration of DOI-capable PET detector panels using uncollimated front-face irradiation

André Kyme, Francisco E. Enríquez-Mier-y-Terán, Steven R. Meikle
Physics in Medicine and Biology
Radiation Detection and Scintillator Technologies
article

Calibration of DOI-capable PET detector panels using uncollimated front-face irradiation

André Kyme, Francisco E. Enríquez-Mier-y-Terán, Steven R. Meikle
article en

Abstract

OBJECTIVE: Gold-standard depth-of-interaction (DOI) calibration using collimated gamma-ray irradiation is time-consuming and requires complex experimental setups, making it impractical for system-level calibration of detector arrays. This work investigates an efficient method for DOI and energy calibration of detector panels using uncollimated irradiation, in which gamma rays are incident parallel, or nearly parallel, to the crystal depth direction. Approach. The 511-keV photopeak location on a dual-ended readout PET detector block as a function of crystal depth was first evaluated using both collimated and uncollimated 22Na source irradiation to determine whether the latter yields comparable estimates when DOI calibration parameters are known. A 4 × 4 dual-ended readout PET detector panel was then assembled, and three detector blocks were calibrated using the gold-standard method. Two DOI calibration approaches based on uncollimated irradiation-a physics-informed model and a multilayer perceptron (MLP)-were compared against the gold-standard calibration. Finally, the detector panel was calibrated for DOI and energy using the MLP-based approach. Main Results. The median relative root mean squared error (RMSE) between second-order polynomial fits to the depth-dependent photopeak location obtained using collimated and uncollimated irradiation was 1%, demonstrating that uncollimated irradiation provides reliable estimates when accurate DOI calibration parameters are available. The RMSE between the gold-standard DOI calibration and the physics-informed and MLP-based approaches ranged from 0.38-0.58 mm and 0.36-0.61 mm, respectively, with no statistically significant difference. However, DOI resolution estimates from the MLP-based approach outperformed those of the physics-informed model, favouring its use for full detector panel calibration. After saturation correction, the detector panel achieved a mean energy resolution of 15.6% and a DOI resolution of 2.0 mm. Significance. The proposed MLP-based calibration requires only a single uniform 511-keV source irradiation, making it simple to implement and sufficiently robust for in situ calibration of DOI-capable PET detector arrays.

Physics in Medicine and Biology
The University of Sydney (AU)
Affordable and clean energy
Openalex Percentile: Top 31%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.