Cross-Platform Retrieval of a Chronically Implanted Leadless Pacemaker Using a Dedicated Retrieval System

BACKGROUND: Leadless pacemakers are increasingly used in patients in whom transvenous pacing leads are undesirable. However, management at battery depletion remains challenging, particularly for chronically implanted devices. CASE SUMMARY: A 74-year-old woman with prior bioprosthetic tricuspid valve replacement, atrial fibrillation, and complete atrioventricular block underwent leadless pacemaker implantation in 2019. At follow-up, device interrogation demonstrated battery depletion. A new leadless pacemaker was implanted via right femoral venous access. The chronically implanted device, located in the mid-right ventricular septum, was subsequently retrieved using a trilobed snare system. Engagement required multiple attempts because of difficulty achieving coaxial alignment; however, after capture, the device was recaptured and removed with minimal resistance and without arrhythmia, pacing instability, or complication. CONCLUSION: This case demonstrates the feasibility of cross-platform retrieval of a chronically implanted leadless pacemaker after prolonged dwell time in selected patients.

Authors

Institutions

Publication Details

Journal
JACC Case Reports
Published
2026-07-01
DOI
https://doi.org/10.1016/j.jaccas.2026.109138
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cross-Platform Retrieval of a Chronically Implanted Leadless Pacemaker Using a Dedicated Retrieval System

Apichai Pokawattana, Surachat Jaroonpipatkul
JACC Case Reports
Cardiac pacing and defibrillation studies
article

Cross-Platform Retrieval of a Chronically Implanted Leadless Pacemaker Using a Dedicated Retrieval System

Apichai Pokawattana, Surachat Jaroonpipatkul
article en

Abstract

BACKGROUND: Leadless pacemakers are increasingly used in patients in whom transvenous pacing leads are undesirable. However, management at battery depletion remains challenging, particularly for chronically implanted devices. CASE SUMMARY: A 74-year-old woman with prior bioprosthetic tricuspid valve replacement, atrial fibrillation, and complete atrioventricular block underwent leadless pacemaker implantation in 2019. At follow-up, device interrogation demonstrated battery depletion. A new leadless pacemaker was implanted via right femoral venous access. The chronically implanted device, located in the mid-right ventricular septum, was subsequently retrieved using a trilobed snare system. Engagement required multiple attempts because of difficulty achieving coaxial alignment; however, after capture, the device was recaptured and removed with minimal resistance and without arrhythmia, pacing instability, or complication. CONCLUSION: This case demonstrates the feasibility of cross-platform retrieval of a chronically implanted leadless pacemaker after prolonged dwell time in selected patients.

JACC Case Reports
Rangsit University (TH)
Good health and well-being
Openalex Percentile: Top 7%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.