Apnea Testing for Brain Death/Death by Neurologic Criteria in Adults: A Prospective Multicenter Observational Study Assessing the Relationship Between Methodology, Safety, and Duration
IMPORTANCE: Apnea testing is an integral component of brain death (BD) assessments. The optimal method of Apnea Testing is currently not known. OBJECTIVES: To describe the current use of apnea test methods, and compare the effect of the chosen apnea test method (passive oxygenation, continuous positive airway pressure [CPAP], or exogenous Co2) on safety and duration of apnea test in adult BD/death by neurologic criteria (DNC) organ donors. DESIGN: A prospective multicenter observational study. SETTING: Seventy-four ICUs in Ontario, Canada, who participate in organ donation practices. PATIENTS: All BD/DNC assessments in Ontario, Canada, from July 2023 to August 2024. INTERVENTIONS: None. MAIN OUTCOMES AND MEASURES: Outcomes included the rate of apnea test attempts, completions, and adverse events. We also measured the incidence of each method used and the duration of the apnea test. RESULTS: During the 1-year study period, a total of 368 BD/DNC assessments were performed, of which 361 (98%) attempted an apnea test. Of the 361 apnea tests attempted, 236 (65%) used passive oxygenation (tracheal insufflation), 103 (29%) used CPAP-based methods, and 22 (6%) used exogenous Co2. Nine tests were not completed: seven were terminated due to adverse events (all with passive oxygenation; five hypoxemia, two hemodynamic instability) and two due to observed respiratory effort. All adverse events occurred with the passive oxygenation method (p = 0.20). No statistically significant differences were seen in apnea test duration between methods. The median test durations were 12 minutes (interquartile range [IQR], 10-17 min), 12 minutes (IQR, 8-15 min), and 15 minutes (IQR, 11-25 min) for passive oxygenation, positive pressure, and exogenous Co2, respectively. CONCLUSIONS AND RELEVANCE: In this large multicenter study, passive oxygenation was associated with a nonsignificant increase in adverse events compared with CPAP-based and exogenous Co2 methods. Exogenous Co2 did not shorten apnea test time. These findings support further investigation of CPAP-based methods as an alternative approach to apnea testing and refinement of Co2 delivery parameters.
Authors
- John Basmaji (ORCID: https://orcid.org/0000-0001-9749-1747)
- Janice Beitel
- Sean Cuninghame (ORCID: https://orcid.org/0000-0002-2594-6121)
- Soliman Kf
- Jeffrey M. Singh (ORCID: https://orcid.org/0000-0003-3499-574X)
- Marat Slessarev (ORCID: https://orcid.org/0000-0003-1181-0706)
- Beth Paltser
- James Duffin (ORCID: https://orcid.org/0000-0003-2270-7392)
- Michael Hartwick (ORCID: https://orcid.org/0000-0002-2888-6996)
- Andrew Healey
- J. Gordon Boyd
- Ebenezer Ogunsakin
- Michelle Snyder-Salehi
- David Katz
- Alexander Yoshiki
Institutions
- Western University (CA)
- University Health Network (CA)
- University of Ottawa (CA)
- University of Toronto (CA)
- Queen's University (CA)
- Lakeridge Health (CA)
- Thunder Bay Regional Health Sciences Centre (CA)
- Trillium Therapeutics (Canada) (CA)
- McMaster University (CA)
Publication Details
- Journal
- Critical Care Explorations
- Published
- 2026-07-01
- DOI
- https://doi.org/10.1097/cce.0000000000001437
- Primary Topic
- Organ Donation and Transplantation
- Type
- article
- Field-Weighted Citation Impact
- 0.00