Integration of Plano-Convex Lenses for Enhanced Fluorescent Signal in Centrifugal Microfluidic Systems

We present a method for enhancing fluorescence signals in centrifugal microfluidic systems by integrating a plano-convex lens into the optical path of a fluorescence detector, effectively focusing emitted light onto a single point. Two-dimensional computational simulations were first conducted to optimize the lens design and positioning, resulting in a 1.7-fold increase in ray collection efficiency compared to configurations without the lens. When the optimally designed plano-convex lens was incorporated into the three-dimensional detection chamber of an actual centrifugal microfluidic system, fluorescence intensities from fluorescein solutions increased by approximately 40–80-fold across most of the tested concentration range. Finally, we applied this strategy to enhance fluorescence signals generated by reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays targeting Influenza B virus, where the lens-integrated disc achieved approximately 60-fold higher fluorescence signals than the lens-free disc. These findings indicate that this strategy can substantially improve fluorescence detection sensitivity in assays employing similar optical configurations and detection principles.

Authors

Publication Details

Journal
Biosensors and Bioelectronics X
Published
2026-07-01
DOI
https://doi.org/10.1016/j.biosx.2026.100815
Primary Topic
Electrowetting and Microfluidic Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integration of Plano-Convex Lenses for Enhanced Fluorescent Signal in Centrifugal Microfluidic Systems

Hyun Gyu Park, Jayeon Song, Jung Seok Yoo, Dong Yeon Jo et al.
Biosensors and Bioelectronics X
Electrowetting and Microfluidic Technologies
article

Integration of Plano-Convex Lenses for Enhanced Fluorescent Signal in Centrifugal Microfluidic Systems

Hyun Gyu Park, Jayeon Song, Jung Seok Yoo, Dong Yeon Jo, RaKyeom Kim, Soohyun Kim
article en

Abstract

We present a method for enhancing fluorescence signals in centrifugal microfluidic systems by integrating a plano-convex lens into the optical path of a fluorescence detector, effectively focusing emitted light onto a single point. Two-dimensional computational simulations were first conducted to optimize the lens design and positioning, resulting in a 1.7-fold increase in ray collection efficiency compared to configurations without the lens. When the optimally designed plano-convex lens was incorporated into the three-dimensional detection chamber of an actual centrifugal microfluidic system, fluorescence intensities from fluorescein solutions increased by approximately 40–80-fold across most of the tested concentration range. Finally, we applied this strategy to enhance fluorescence signals generated by reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays targeting Influenza B virus, where the lens-integrated disc achieved approximately 60-fold higher fluorescence signals than the lens-free disc. These findings indicate that this strategy can substantially improve fluorescence detection sensitivity in assays employing similar optical configurations and detection principles.

Biosensors and Bioelectronics X
Affordable and clean energy
Openalex Percentile: Top 11%
Electrowetting and Microfluidic Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.