Leadless Pacemaker Implantation in High‐Risk Patients: Real‐World Outcomes From a Multicenter Israeli Registry

INTRODUCTION: Transvenous pacemakers are effective but carry significant short- and long-term complications. Leadless pacemakers were developed to overcome these limitations, however, data in high-risk patients ineligible for transvenous systems remain limited. AIM: To evaluate the real-world outcomes of leadless pacemaker in high risk bradyarrhythmia patients unsuitable for transvenous pacing. METHODS: A retrospective, observational, multi center registry (MLPI) across four Israeli hospitals, included all patients undergoing leadless pacemaker implantation July 2021-December 2022 within a national pilot program. Indications included venous abnormalities, prior device infection, Twiddler's syndrome or high infection risk. Procedural success, complications, electrical performance, and mortality were assessed at 48 h, 30 days, and 12 months. RESULTS: A total of 138 patients were enrolled, with a high comorbidity burden (hypertension 74%, heart failure 44%, chronic kidney disease 36%). High grade atrioventricular block was the main pacing indication (70%), and the leading reason for leadless implantation (54%) was high infection risk. Implantation was successful in 98% of the patients, almost all with Micra. Acute complications occurred in 2.9%, (primarily pericardial effusion); three patients (2.2%) died within 48 h. At 1-year, electrical performance remained stable, with low pacing thresholds (median 0.5 V), preserved sensing, and declining impedance. Two late complications occurred (tamponade, loss of capture). The 1-year cumulative complication rate was 4.7%, and all-cause mortality 12.3%. CONCLUSION: Leadless pacemaker implantation in a very high-risk Israeli cohort achieved high procedural success, stable performance, and low complication rate, supporting its role as a safe and effective alternative to conventional pacing systems.

Authors

Institutions

Publication Details

Journal
Pacing and Clinical Electrophysiology
Published
2026-07-02
DOI
https://doi.org/10.1111/pace.70333
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Leadless Pacemaker Implantation in High‐Risk Patients: Real‐World Outcomes From a Multicenter Israeli Registry

Gregory Golovchiner, Moshe Katz, Yoav Michowitz, Alon Barsheshet et al.
Pacing and Clinical Electrophysiology
Cardiac pacing and defibrillation studies
article

Leadless Pacemaker Implantation in High‐Risk Patients: Real‐World Outcomes From a Multicenter Israeli Registry

Gregory Golovchiner, Moshe Katz, Yoav Michowitz, Alon Barsheshet, Moshe Rav, David Luria, R Beinart, Marianna Vander
article en

Abstract

INTRODUCTION: Transvenous pacemakers are effective but carry significant short- and long-term complications. Leadless pacemakers were developed to overcome these limitations, however, data in high-risk patients ineligible for transvenous systems remain limited. AIM: To evaluate the real-world outcomes of leadless pacemaker in high risk bradyarrhythmia patients unsuitable for transvenous pacing. METHODS: A retrospective, observational, multi center registry (MLPI) across four Israeli hospitals, included all patients undergoing leadless pacemaker implantation July 2021-December 2022 within a national pilot program. Indications included venous abnormalities, prior device infection, Twiddler's syndrome or high infection risk. Procedural success, complications, electrical performance, and mortality were assessed at 48 h, 30 days, and 12 months. RESULTS: A total of 138 patients were enrolled, with a high comorbidity burden (hypertension 74%, heart failure 44%, chronic kidney disease 36%). High grade atrioventricular block was the main pacing indication (70%), and the leading reason for leadless implantation (54%) was high infection risk. Implantation was successful in 98% of the patients, almost all with Micra. Acute complications occurred in 2.9%, (primarily pericardial effusion); three patients (2.2%) died within 48 h. At 1-year, electrical performance remained stable, with low pacing thresholds (median 0.5 V), preserved sensing, and declining impedance. Two late complications occurred (tamponade, loss of capture). The 1-year cumulative complication rate was 4.7%, and all-cause mortality 12.3%. CONCLUSION: Leadless pacemaker implantation in a very high-risk Israeli cohort achieved high procedural success, stable performance, and low complication rate, supporting its role as a safe and effective alternative to conventional pacing systems.

Pacing and Clinical Electrophysiology
Tel Aviv University (IL), Hebrew University of Jerusalem (IL), Sheba Medical Center (IL), Hadassah Medical Center (IL), Rabin Medical Center (IL), Shaare Zedek Medical Center (IL)
Good health and well-being
Openalex Percentile: Top 8%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.