Temperature-Dependent Nonlinear Calibration of Glass pH Electrodes for Negative pH Applications

High Resolution Image Download MS PowerPoint Slide Glass pH electrodes are widely used to estimate proton activity ( a H + ) in aqueous solutions. However, at high proton activity, conventional linear calibration using standard NIST/DIN buffers breaks down due to nonlinear electrode response and strong nonideality, leading to severe pH overestimation. To alleviate this limitation, this study develops and validates a nonlinear, temperature-corrected calibration protocol that extends the measurable and reliable range of pH using glass electrodes down to (pH = −log a H + ) = −5 (proton activity of 10 5 ) over a temperature range between 5 and 60 °C. The calibration is done using NIST buffers (pH 1.68 to 10.01) and sulfuric acid standards (concentrations ranging between 0.16 mmol·L –1 and 9.69 mol·L –1 H 2 SO 4 ). Proton activities are calculated using the Pitzer model with the MacInnes assumption implemented in PHREEQC. At a given temperature, the response curve between pH and the electrode electromotive force in the low to negative pH range is modeled best with a logistic equation. Incorporation of temperature-dependent parameters enables construction of continuous nonlinear calibration curves across the studied temperature range. Application of this calibration protocol reduces systematic pH overestimation by up to >3 pH units and yields accurate proton activity under strongly acidic conditions. Sensitivity analysis demonstrates that meaningful measurements are achievable down to approximately pH ≈ −5, below which signal-to-noise constraints dominate. This work establishes a transferable and practical methodology that extends the operational range of conventional glass electrodes by several orders of magnitude in proton activity, enabling more reliable pH measurements in extreme natural and industrial environments.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-07-02
DOI
https://doi.org/10.1021/acsomega.6c01903
Primary Topic
Chemical and Physical Properties in Aqueous Solutions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temperature-Dependent Nonlinear Calibration of Glass pH Electrodes for Negative pH Applications

Sarawud Saleesongsom, Yves Plancherel, Dominik Weiss
ACS Omega
Chemical and Physical Properties in Aqueous Solutions
article

Temperature-Dependent Nonlinear Calibration of Glass pH Electrodes for Negative pH Applications

Sarawud Saleesongsom, Yves Plancherel, Dominik Weiss
article en

Abstract

High Resolution Image Download MS PowerPoint Slide Glass pH electrodes are widely used to estimate proton activity ( a H + ) in aqueous solutions. However, at high proton activity, conventional linear calibration using standard NIST/DIN buffers breaks down due to nonlinear electrode response and strong nonideality, leading to severe pH overestimation. To alleviate this limitation, this study develops and validates a nonlinear, temperature-corrected calibration protocol that extends the measurable and reliable range of pH using glass electrodes down to (pH = −log a H + ) = −5 (proton activity of 10 5 ) over a temperature range between 5 and 60 °C. The calibration is done using NIST buffers (pH 1.68 to 10.01) and sulfuric acid standards (concentrations ranging between 0.16 mmol·L –1 and 9.69 mol·L –1 H 2 SO 4 ). Proton activities are calculated using the Pitzer model with the MacInnes assumption implemented in PHREEQC. At a given temperature, the response curve between pH and the electrode electromotive force in the low to negative pH range is modeled best with a logistic equation. Incorporation of temperature-dependent parameters enables construction of continuous nonlinear calibration curves across the studied temperature range. Application of this calibration protocol reduces systematic pH overestimation by up to >3 pH units and yields accurate proton activity under strongly acidic conditions. Sensitivity analysis demonstrates that meaningful measurements are achievable down to approximately pH ≈ −5, below which signal-to-noise constraints dominate. This work establishes a transferable and practical methodology that extends the operational range of conventional glass electrodes by several orders of magnitude in proton activity, enabling more reliable pH measurements in extreme natural and industrial environments.

ACS Omega
Imperial College London (GB)
Openalex Percentile: Top 13%
Chemical and Physical Properties in Aqueous Solutions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.