Thermoforming time variability of PET-G and TPU aligner sheets across consecutive thermoforming cycles: an in vitro study

BACKGROUND: Thermoforming time is a critical parameter in the fabrication of thermoformed orthodontic aligners, as it influences polymer softening, material adaptation, and dimensional consistency. Manufacturer-recommended heating durations are typically based on standardized conditions and may not reflect the dynamic thermal behavior of thermoforming units during consecutive fabrication cycles. Empirical data quantifying heating-time variation and stabilization patterns remain limited. METHODS: This in vitro study evaluated heating-time variation across 20 consecutive thermoforming cycles in two commercially available thermoplastic aligner materials: a multilayer polyethylene terephthalate glycol/thermoplastic polyurethane composite (Zendura FLX) and a single-layer thermoplastic polyurethane sheet (Maxflex), both with a nominal thickness of 0.76 mm. Each material underwent ten independent experimental sessions (total n = 200 cycles per material) using a standardized pressure-forming unit under controlled environmental conditions (23 ± 1 °C; 50 ± 5% humidity). Heating was terminated at a predefined sag depth of 16 mm, determined using a laser-based measurement system. Linear mixed-effects models were used to assess cycle-dependent variation, and simple linear regression was applied to the pre-stabilization phase. RESULTS: Heating time progressively decreased across consecutive thermoforming cycles for both materials. Zendura FLX stabilized from cycle 6 onward, with a steady-state mean of 64.59 ± 3.58 s. Maxflex stabilized from cycle 12 onward, with a steady-state mean of 69.37 ± 1.12 s. During the transient phase, heating time decreased linearly by 8.66 s per cycle for Zendura FLX (R² = 0.78) and 4.17 s per cycle for Maxflex (R² = 0.97). Both transient and steady-state heating durations were significantly longer than Supplier-Recommended Thermoforming Times (p < 0.0001). CONCLUSIONS: Heating time during thermoforming decreased across consecutive cycles before reaching material-specific stabilization thresholds. For both materials, experimentally determined heating durations exceeded manufacturer-recommended times under controlled laboratory conditions, suggesting that thermoforming behavior may vary dynamically during repeated fabrication cycles.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-07-02
DOI
https://doi.org/10.1186/s12903-026-09148-y
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermoforming time variability of PET-G and TPU aligner sheets across consecutive thermoforming cycles: an in vitro study

Thị Hường Phạm, Ngoc Anh Thu Pham, Thi Bich Van Tran
BMC Oral Health
Orthopaedic implants and arthroplasty
article

Thermoforming time variability of PET-G and TPU aligner sheets across consecutive thermoforming cycles: an in vitro study

Thị Hường Phạm, Ngoc Anh Thu Pham, Thi Bich Van Tran
article en

Abstract

BACKGROUND: Thermoforming time is a critical parameter in the fabrication of thermoformed orthodontic aligners, as it influences polymer softening, material adaptation, and dimensional consistency. Manufacturer-recommended heating durations are typically based on standardized conditions and may not reflect the dynamic thermal behavior of thermoforming units during consecutive fabrication cycles. Empirical data quantifying heating-time variation and stabilization patterns remain limited. METHODS: This in vitro study evaluated heating-time variation across 20 consecutive thermoforming cycles in two commercially available thermoplastic aligner materials: a multilayer polyethylene terephthalate glycol/thermoplastic polyurethane composite (Zendura FLX) and a single-layer thermoplastic polyurethane sheet (Maxflex), both with a nominal thickness of 0.76 mm. Each material underwent ten independent experimental sessions (total n = 200 cycles per material) using a standardized pressure-forming unit under controlled environmental conditions (23 ± 1 °C; 50 ± 5% humidity). Heating was terminated at a predefined sag depth of 16 mm, determined using a laser-based measurement system. Linear mixed-effects models were used to assess cycle-dependent variation, and simple linear regression was applied to the pre-stabilization phase. RESULTS: Heating time progressively decreased across consecutive thermoforming cycles for both materials. Zendura FLX stabilized from cycle 6 onward, with a steady-state mean of 64.59 ± 3.58 s. Maxflex stabilized from cycle 12 onward, with a steady-state mean of 69.37 ± 1.12 s. During the transient phase, heating time decreased linearly by 8.66 s per cycle for Zendura FLX (R² = 0.78) and 4.17 s per cycle for Maxflex (R² = 0.97). Both transient and steady-state heating durations were significantly longer than Supplier-Recommended Thermoforming Times (p < 0.0001). CONCLUSIONS: Heating time during thermoforming decreased across consecutive cycles before reaching material-specific stabilization thresholds. For both materials, experimentally determined heating durations exceeded manufacturer-recommended times under controlled laboratory conditions, suggesting that thermoforming behavior may vary dynamically during repeated fabrication cycles.

BMC Oral Health
University of Medicine and Pharmacy at Ho Chi Minh City (VN)
Openalex Percentile: Top 6%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.